2% Rabatt auf Online-Bestellungen
Details
installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive cable with rodent protection (optical fibre) cable to a large extent oil resistant flame retardant acc. IEC 60332-3-24 screened cable not for application in power circuits min. installation temperature -5 °C cable suitable for direct burial
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
101073RE-2X(St)YSWAY-fl 1X2X1.3 BK IEC 332-3-24
in stock
Aufmachung

Log in to see prices

New here? Register now
Preis
101151RE-2X(St)YSWAY-fl 1X2X1.3 BU IEC 332-3-24
in stock
AufmachungPreis
101158RE-2X(St)YBKAY-fl PiMF 2X2X1.3 BK IEC 332-3-24
on request
AufmachungPreis
101273RE-2X(St)YBKAY-fl PiMF 4X2X1.3 BK IEC 332-3-24
on request
AufmachungPreis
101159RE-2X(St)YBKAY-fl PiMF 2X2X1.3 BU IEC 332-3-24
on request
AufmachungPreis
101274RE-2X(St)YBKAY-fl PiMF 4X2X1.3 BU IEC 332-3-24
on request
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Standard EN 50288-7 (with ref. to)
Conductor material copper, bare
Conductor construction class 2, 7-wired construction
Insulation XLPE
Stranding unit pair
Stranding Layers
Core wrapping plastic foil
Material inner sheath PVC
Screen plastic coated Al-foil + copper drain wire, tinned
Armour round steel wire, galvanized
Sheathing material PVC
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
UV-resistant yes
Oil-resistant yes
For outdoor use yes
Permitted outer cable temperature, fixed, °C -30 - +70 °C
Permitted outer cable temperature, moved, °C -5 - +50 °C
Bending radius, fixed installation 12 x Ø
Insulation resistance 1000 MOhmxkm
Core identification black/white with numbers
Nominal cross section, sqmm 1.3 mm²
Conductor resistance 14.2 Ohm/km
metal base Cu 100 EUR/100 kg
Unit of measurement metre

For data communication with transmission rates up to 200 kBit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, outdoors and direct burial in earth.The types with blue outer sheath are suitable for intrinsically safe installation -Ex i- in hazardous areas. Core identification: black-white(-orange) with sequential numbering

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator