2% Rabatt auf Online-Bestellungen
Details
flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free min. installation temperature +5 °C cable with VDE-certification cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
020278NHXMH-J 1X1.5 GY
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
020279NHXMH-J 1X2.5 GY
on request
AufmachungPreis
020232NHXMH-J 1X4 GY
in stock
AufmachungPreis
020280NHXMH-J 1X6 GY
in stock
AufmachungPreis
020281NHXMH-J 1X10 GY
in stock
AufmachungPreis
020233NHXMH-J 1X16 GY
in stock
AufmachungPreis
020282NHXMH-J 1X25 GY
on request
AufmachungPreis
020185NHXMH-J 3X1.5 GY
in stock
AufmachungPreis
020188NHXMH-J 3X2.5 GY
in stock
AufmachungPreis
020206NHXMH-J 3X4 GY
in stock
AufmachungPreis
020207NHXMH-J 3X6 GY
in stock
AufmachungPreis
020208NHXMH-J 3X10 GY
in stock
AufmachungPreis
020192NHXMH-J 4X1.5 GY
in stock
AufmachungPreis
020209NHXMH-J 4X2.5 GY
in stock
AufmachungPreis
020187NHXMH-J 4X4 GY
on request
AufmachungPreis
020189NHXMH-J 4X6 GY
in stock
AufmachungPreis
020210NHXMH-J 4X10 GY
on request
AufmachungPreis
020190NHXMH-J 4X16 GY
on request
AufmachungPreis
020191NHXMH-J 4X25 GY
on request
AufmachungPreis
020211NHXMH-J 4X35 GY
on request
AufmachungPreis
020214NHXMH-J 5X1.5 GY
in stock
AufmachungPreis
020195NHXMH-J 5X2.5 GY
in stock
AufmachungPreis
020179NHXMH-J 5X4 GY
in stock
AufmachungPreis
020196NHXMH-J 5X6 GY
in stock
AufmachungPreis
020212NHXMH-J 5X10 GY
in stock
AufmachungPreis
020194NHXMH-J 5X16 GY
in stock
AufmachungPreis
020277NHXMH-J 5X25 GY
on request
AufmachungPreis
020197NHXMH-J 7X1.5 GY
on request
AufmachungPreis
020213NHXMH-J 7X2.5 GY
on request
AufmachungPreis
020229NHXMH-J 10X1.5 GY
on request
AufmachungPreis
020230NHXMH-J 12X1.5 GY
in stock
AufmachungPreis
020231NHXMH-J 24X1.5 GY
on request
AufmachungPreis
020296NHXMH-J 24X2.5 GY
on request
AufmachungPreis
020198NHXMH-O 1X1.5 GY
on request
AufmachungPreis
020199NHXMH-O 1X2.5 GY
on request
AufmachungPreis
020200NHXMH-O 1X4 GY
on request
AufmachungPreis
020201NHXMH-O 1X6 GY
on request
AufmachungPreis
020202NHXMH-O 1X10 GY
on request
AufmachungPreis
020203NHXMH-O 1X16 GY
on request
AufmachungPreis
020204NHXMH-O 2X1.5 GY
in stock
AufmachungPreis
020205NHXMH-O 2X2.5 GY
on request
AufmachungPreis
020327NHXMH-O 2X4 GY
on request
AufmachungPreis
020328NHXMH-O 2X6 GY
on request
AufmachungPreis
020329NHXMH-O 2X10 GY
on request
AufmachungPreis
020234NHXMH-O 4X10 GY
on request
AufmachungPreis
020235NHXMH-O 4X16 GY
on request
AufmachungPreis
020236NHXMH-O 4X25 GY
on request
AufmachungPreis
Customs Tariff Number (code number) 85444991000000000
CPR-classification according to EN 50575 Dca
Standard VDE 0250 T. 214
Conductor material copper, bare
Conductor construction class 1, up from 16 sqmm class 2
Insulation XLPE 2XI1
Sheathing material FRNC-compound HM2
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Max. temperature at conductor, °C 70 °C
Permitted outer cable temperature, fixed, °C -40 - +70 °C
Permitted outer cable temperature, moved, °C 5 - 70 °C
Nominal voltage Uo 300 V
Nominal voltage U 500 V
Core identification colours acc. to VDE 0293 (HD308)
Conductor shape round
Colour of outer sheath grey
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Low-smoke, zero-halogen, flame-retardant building wire, for installation on and under plaster in dry and wet rooms, as well as in concrete (except for shaken, jolted, tamped concrete). For indoor use only, primarily in buildings with a high concentration of people and material assets.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

NHXMH-J – The cable for improved response in case of fire

The installation cable with the designation NHXMH-J is a halogen free sheath cable. Most sheath cables are multi-core cables in which the cores are surrounded by a resistant PVC sheath. NHXMH-J therefore can be seen as a halogen-free alternative to the PVC installation cable NYM. The core isolation of the NHXMH consists of cross-linked polyethylene (XLPE), whereas the outer sheath is made of a halogen-free polymer compound. Since the sheath cable is halogen-free, it has improved reaction properties in case of fire. This improved reaction in case of fire is achieved by the characteristics of the cable, which only allow minimal flame propagation and smoke generation. In Germany, electrical cables with improved fire behaviour are cables which must meet the test specifications of IEC 60332-3-24 (Cat. C). The halogen-free sheath cable NHXMH is the most frequently used type of cable in this country, with improved reaction in case of fire.

Where is NHXMH-J used?

The halogen-free sheath cable is preferably used in places and buildings where there is a high concentration of people and/or material values, i.e. where enormous damage could be caused to people and material in case of fire. The previously mentioned improved fire reaction of NHXMH-J ensures low smoke generation in case of fire and prevents consequential fire damage caused by gases that contain halogen. Common examples of buildings or rooms with a high concentration of people and material assets are industrial plants, airports and hotels, underground railways, railway stations, hospitals, schools and much more.

Structure of NHXMH-J

NHXMH consists of single or multi-stranded, round copper conductors. The cores are stranded in layers and the core isolation consists of polyethylene; the outer sheath is grey and consists of one halogen free polymer compound. Core identification is done according to DIN VDE 0293-308. You can find more precise information in the NHXMH-J 3x1.5 data sheet.
Summary of the structure of NHXMH-J:
1. Round copper conductor, single or multi-stranded
2. Core isolation made of cross-linked polyethylene (XLPE)
3. Core sheathing made of halogen-free filling compound
4. Grey outer sheath made of halogen-free polymer

What are the requirements for installing NHXMH-J?

Since there are many places with high concentrations of material assets, the cable can be used in many places. But which requirements have to be considered during installation? In principle, it is possible to have a permanent installation of NHXMH-J in damp and wet rooms. NHXMH can be installed above, within and below render as well as in brickwork. Besides, the possibility of installation in concrete cannot be excluded, although the cable should not be embedded directly in shaken, vibrated or compressed concrete. What about using NHXMH-J outdoors? Outdoor installation is also possible as long as the cable is not exposed to direct sunlight i.e. must be installed in a protected manner.

NHMH-J: What's the difference to NHXMH-J?

In contrast to NHXMH, (N)HMH cables are not standardised, have no improved reaction in case of fire and their PE core isolation is not cross-linked. (N)HMH cables are also halogen-free, but they are not as easily available as NHXMH or NHXH. NHMH is therefore unsuitable for use in rooms with high concentrations of persons and material values, because the cable does not meet the requirements of DIN VDE 0100-482.

NHXMH-J: Meaning of the abbreviation

The meaning of the abbreviation is illustrated using the cable NHXMH-J 3x2.5 as an example:
N: Standard cable according to VDE
HX: Isolation made of cross-linked polyethylene (XLPE)
M: sheathed cable
H: halogen-free sheath compound
-J: with green-yellow protective conductor
3: 3 cores
x: "amount"
2.5: 2.5 mm² conductor cross-section

Conclusion on NHXMH-J as a halogen-free alternative

The halogen free cable NHXMH-J does not develop any corrosive fire gases, has no fire propagation properties and minimal smoke generation – thus significantly improving reaction in case of fire. NHXMH is an environmentally conscious alternative to flexible rubber cables or plastic cables, and can be installed in many environments: Installation in render, brickwork and embedding in concrete (except for shaken and compressed concrete) can be done without problems.
All NHXMH-J type halogen-free sheath cables are manufactured at Faber according to the highest quality standards. In our online shop, you can find NHXMH-J and NHXMH-O sheath cables with one to 24 cores, e.g. NHXMH-J 03x1.5 with three cores and NHXMH-J 05x6 with five cores. All lines and cables can be ordered from Faber by the meter.

Technical data for NHXMH-J at a glance

Here you can see the technical data for the halogen-free sheath cable NHXMH-J at a glance:
• Rated voltage: 300 / 500 V
• Test voltage: 2,000 V
• Max. operating temperature: 70 °C on conductor
• Min. operating temperature: -40 °C
• Installation temperature: max. 60 °C / min. +5 °C
• Flame retardant according to VDE 0482-266-2-4
• Conforms to the Low Voltage Directive