(N)HXCH E30 4X35/16 OG
Your p/nr.
MOQ
MOQ: 2 km
Delivery time: approx. 15 weeks
MOQ
MOQ: 2 km
Delivery time: approx. 15 weeks
MOQ
MOQ: 2 km
Delivery time: approx. 15 weeks
MOQ
MOQ: 2 km
Delivery time: approx. 15 weeks
in stock
Discounted residual lengths
Your p/nr.
Discounted residual lengths
Your p/nr.
Customs Tariff Number (code number) | 85444995900000000 |
Standard | VDE 0266 |
Conductor material | copper, bare |
Conductor construction | class 1, from 25 sqmm class 2 |
Insulation | FRNC-compound HI1 |
Concentric conductor | Cu |
Sheathing material | FRNC-compound HM1 |
Colour of outer sheath | orange |
Flame-retardant | VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C) |
Smoke density | DIN EN 61034/IEC 61034 |
Halogen-free | DIN EN 50267/IEC 60754 |
Fire-resistant | VDE 0472-814/IEC 60331-1/IEC 60331-11 (FE 180)/EN 50200 |
Circuit integrity | E30 |
Max. temperature at conductor, °C | 90 °C |
Permitted outer cable temperature, fixed, °C | -5 - +70 °C |
Bending radius, fixed installation | 12 x Ø |
Core identification | colours acc. to HD 308; more than 5 cores: numbers |
Conductor shape | round |
Conductor shape (Faber) | RM |
Number of cores | 4 |
Nominal cross section, sqmm | 35 mm² |
Conductor resistance | 0.524 Ohm/km |
Ampacity in air (30 °C) | 165 A |
Cross-section of concentric conductor | 16 |
Bending radius, fixed installation | 420 mm |
outer diameter approx. | 31.10 mm |
Colour of outer sheath | orange |
Copper weight (GER) | 1526 |
metal base Cu | 0 EUR/100 kg |
net weight per 1000 | 2002 kg |
Unit of measurement | metre |
VDE | yes |
Nominal voltage | 0,6/1 kV |
Sheathing material | FRNC-compound |
Cable shape | round |
Halogen-free | yes |
Oil-resistant | no |
Colour | orange |
Conductor construction | class 2 = stranded |
Insulation | FRNC-compound |
For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 /IEC 60331-11 for 180 minutes . Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 °C is approximately four times higher than at 20 °C and the current carrying capacity is reduced respectively.
All images shown here are for illustrations and product reference purposes only.
The discount on our residual lengths is only valid for orders placed via our Faber B2B webshop.