2% Rabatt auf Online-Bestellungen
Details
cable with circuit integrity 90 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C min. installation temperature -5 °C cable with VDE-certification cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
013312(N)HXCH E90 2X2.5/2.5 RE OG
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
011042(N)HXCH E90 3X1.5/1.5 RE OG
in stock
AufmachungPreis
011043(N)HXCH E90 3X2.5/2.5 RE OG
in stock
AufmachungPreis
011209(N)HXCH E90 3X4/4 RE OG
in stock
AufmachungPreis
011208(N)HXCH E90 3X6/6 RE OG
on request
AufmachungPreis
011207(N)HXCH E90 3X10/10 RE OG
on request
AufmachungPreis
011206(N)HXCH E90 3X16/16 OG
on request
AufmachungPreis
011205(N)HXCH E90 3X25/16 OG
on request
AufmachungPreis
011204(N)HXCH E90 3X35/16 OG
on request
AufmachungPreis
011197(N)HXCH E90 3X50/25 RM OG
on request
AufmachungPreis
011203(N)HXCH E90 3X70/35 RM OG
on request
AufmachungPreis
011213(N)HXCH E90 3X95/50 RM OG
on request
AufmachungPreis
011202(N)HXCH E90 3X120/70 RM OG
on request
AufmachungPreis
011201(N)HXCH E90 3X150/70 RM OG
on request
AufmachungPreis
011200(N)HXCH E90 3X185/95 RM OG
on request
AufmachungPreis
011198(N)HXCH E90 3X240/120 RM OG
on request
AufmachungPreis
010995(N)HXCH E90 4X1.5/1.5 RE OG
in stock
AufmachungPreis
010996(N)HXCH E90 4X2.5/2.5 RE OG
in stock
AufmachungPreis
010997(N)HXCH E90 4X4/4 RE OG
in stock
AufmachungPreis
010987(N)HXCH E90 4X6/6 RE OG
in stock
AufmachungPreis
010994(N)HXCH E90 4X10/10 RE OG
in stock
AufmachungPreis
010998(N)HXCH E90 4X16/16 OG
in stock
AufmachungPreis
010999(N)HXCH E90 4X25/16 OG
in stock
AufmachungPreis
010993(N)HXCH E90 4X35/16 OG
in stock
AufmachungPreis
011000(N)HXCH E90 4X50/25 RM OG
on request
AufmachungPreis
011001(N)HXCH E90 4X70/35 RM OG
in stock
AufmachungPreis
011002(N)HXCH E90 4X95/50 RM OG
in stock
AufmachungPreis
011003(N)HXCH E90 4X120/70 RM OG
in stock
AufmachungPreis
011004(N)HXCH E90 4X150/70 RM OG
in stock
AufmachungPreis
011005(N)HXCH E90 4X185/95 RM OG
in stock
AufmachungPreis
011006(N)HXCH E90 4X240/120 RM OG
in stock
AufmachungPreis
011749(N)HXCH E90 5X4/4 RE OG
on request
AufmachungPreis
010988(N)HXCH E90 7X1.5/2.5 RE OG
in stock
AufmachungPreis
011007(N)HXCH E90 7X2.5/2.5 RE OG
in stock
AufmachungPreis
015551(N)HXCH E90 7X6/6RE OG
on request
AufmachungPreis
015364(N)HXCH E90 10X1.5/2.5RE OG
on request
AufmachungPreis
011008(N)HXCH E90 12X1.5/2.5 RE OG
in stock
AufmachungPreis
011009(N)HXCH E90 12X2.5/4 RE OG
in stock
AufmachungPreis
011210(N)HXCH E90 24X1.5/6 RE OG
in stock
AufmachungPreis
011211(N)HXCH E90 24X2.5/10 RE OG
on request
AufmachungPreis
011212(N)HXCH E90 30X1.5/6 RE OG
on request
AufmachungPreis
011199(N)HXCH E90 30X2.5/10 RE OG
on request
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0266
Conductor material copper, bare
Conductor construction class 1, from 25 sqmm class 2
Insulation FRNC-compound HI1
Concentric conductor Cu
Sheathing material FRNC-compound HM1
Colour of outer sheath orange
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Fire-resistant VDE 0472-814/IEC 60331-11 (FE 180)
Circuit integrity E90
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -30 - +90 °C
Permitted outer cable temperature, moved, °C -5 °C
Bending radius, fixed installation 12 x Ø
Core identification colours acc. to HD 308; more than 5 cores: numbers
Conductor shape round
Colour of outer sheath orange
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min. = IEC 331). Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 °C is approximately 4,5 times higher than at 20 °C and the current carrying capacity has to be reduced respectively.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator