• Sprache wechseln DE
    |
    EN
  • Cart
CU/AL
0 0

(N)HXCH FE180/E30

(N)HXCH FE180/E30
cable with circuit integrity 30 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C cable with VDE-certification cable with EAC-approval cable conform to Low Voltage directive

cable with circuit integrity 30 mincable with circuit integrity 30 min

cable with function maintainance 180 mincable with function maintainance 180 min

flame retardant acc. IEC 60332-3-24flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034cable with low smoke IEC 61034

cable halogen-freecable halogen-free

max. permitted temperature at conductor 90 °Cmax. permitted temperature at conductor 90 °C

cable with VDE-certificationcable with VDE-certification

cable with EAC-approvalcable with EAC-approval

cable conform to Low Voltage directivecable conform to Low Voltage directive

  • Item list
  • Technical data
  • Application
  • Technical documents
Standard VDE 0266
Conductor material copper, bare
Conductor class class 1, from 25 sqmm class 2
Insulation FRNC-compound HI1
Concentric conductor Cu
Sheathing material FRNC-compound HM1
Colour outer sheath orange
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Fire-resistant FE 180
Circuit integrity E30
Maximum permitted conductor temperature 90 °C
Permitted outer cable temperature, fixed -5 - +70 °C
Bending radius, fixed installation 12 x DA
Nominal voltage Uo 600 V
Nominal voltage U 1000 V
Maximum permitted operating voltage in three-phase systems 1.2 kV
Test voltage 4 kV
Core identification colours acc. to HD 308; more than 5 cores: numbers
Colour of outer sheath orange

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min.= IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 °C is approximately four times higher than at 20 °C and the current carrying capacity is reduced respectively.

p/nr. Part name Availability Packaging EUR netto pre-metal per 1.000
011505 NHXCH E30 02X1,5/1,5 RE OR on request
Stock choose
-
011506 NHXCH E30 02X2,5/2,5 RE OR on request
Stock choose
-
011507 NHXCH E30 02X4/4 RE OR Stock
Stock choose
-
013253 NHXCH E30 02X6/6 RE OR on request
Stock choose
-
011278 NHXCH E30 03X1,5/1,5 RE OR Stock
Stock choose
-
011215 NHXCH E30 03X2,5/2,5 RE OR Stock
Stock choose
-
013753 NHXCH E30 03X4/4 RE OR on request
Stock choose
-
013754 NHXCH E30 03X6/6 RE OR on request
Stock choose
-
013755 NHXCH E30 03X10/10 RE OR on request
Stock choose
-
013756 NHXCH E30 03X16/16 RE OR on request
Stock choose
-
013856 NHXCH E30 03X25/16 OR on request
Stock choose
-
013857 NHXCH E30 03X50/25 RM OR on request
Stock choose
-
013858 NHXCH E30 03X70/35 RM OR on request
Stock choose
-
013859 NHXCH E30 03X95/50 RM OR on request
Stock choose
-
013860 NHXCH E30 03X120/70 RM OR on request
Stock choose
-
011831 NHXCH E30 03X150/70 RM OR on request
Stock choose
-
011832 NHXCH E30 03X185/95 RM OR on request
Stock choose
-
011280 NHXCH E30 04X1,5/1,5 RE OR Stock
Stock choose
-
011281 NHXCH E30 04X2,5/2,5 RE OR Stock
Stock choose
-
011282 NHXCH E30 04X4/4 RE OR Stock
Stock choose
-
011226 NHXCH E30 04X6/6 RE OR Stock
Stock choose
-
011224 NHXCH E30 04X10/10 RE OR Stock
Stock choose
-
011181 NHXCH E30 04X16/16 OR Stock
Stock choose
-
011167 NHXCH E30 04X25/16 OR Stock
Stock choose
-
011183 NHXCH E30 04X35/16 OR Stock
Stock choose
-
011227 NHXCH E30 04X50/25 RM OR Stock
Stock choose
-
011168 NHXCH E30 04X70/35 RM OR Stock
Stock choose
-
011184 NHXCH E30 04X95/50 RM OR Stock
Stock choose
-
011274 NHXCH E30 04X120/70 RM OR Stock
Stock choose
-
011275 NHXCH E30 04X150/70 RM OR Stock
Stock choose
-
011276 NHXCH E30 04X185/95 RM OR Stock
Stock choose
-
011277 NHXCH E30 04X240/120 RM OR Stock
Stock choose
-
011279 NHXCH E30 07X1,5/2,5 RE OR Stock
Stock choose
-
011283 NHXCH E30 07X2,5/2,5 RE OR on request
Stock choose
-
011284 NHXCH E30 12X1,5/2,5 RE OR Stock
Stock choose
-
011285 NHXCH E30 12X2,5/4 RE OR Stock
Stock choose
-
014465 NHXCH E30 14X2,5/6 RE OR on request
Stock choose
-
013621 NHXCH E30 19X1,5/2,5 RE OR on request
Stock choose
-
013622 NHXCH E30 24X1,5/2,5 RE OR on request
Stock choose
-
013820 NHXCH E30 19X1,5/4 RE OR on request
Stock choose
-
013821 NHXCH E30 24X1,5/6 RE OR on request
Stock choose
-

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metall regarding the daily market price.

The offered products of this online shop are aimed at entrepreneurs according to §14 BGB, traders, freelancer and public organisations. There is no sale for consumers.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-289
Fax +49 681 97 11-289