• Sprache wechseln DE
    |
    EN
  • Cart
CU/AL
0 0

(N)HXCH FE180/E90

(N)HXCH FE180/E90
cable with circuit integrity 90 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C cable with VDE-certification cable with EAC-approval cable conform to Low Voltage directive

cable with circuit integrity 90 mincable with circuit integrity 90 min

cable with function maintainance 180 mincable with function maintainance 180 min

flame retardant acc. IEC 60332-3-24flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034cable with low smoke IEC 61034

cable halogen-freecable halogen-free

max. permitted temperature at conductor 90 °Cmax. permitted temperature at conductor 90 °C

cable with VDE-certificationcable with VDE-certification

cable with EAC-approvalcable with EAC-approval

cable conform to Low Voltage directivecable conform to Low Voltage directive

  • Item list
  • Technical data
  • Application
  • Technical documents
Standard VDE 0266
Conductor material copper, bare
Conductor class class 1, from 25 sqmm class 2
Insulation FRNC-compound HI1
Concentric conductor Cu
Sheathing material FRNC-compound HM1
Colour outer sheath orange
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Fire-resistant FE 180
Circuit integrity E90
Maximum permitted conductor temperature 90 °C
Permitted outer cable temperature, fixed -5 - +70 °C
Bending radius, fixed installation 12 x DA
Nominal voltage Uo 600 V
Nominal voltage U 1000 V
Core identification colours acc. to HD 308; more than 5 cores: numbers
Colour of outer sheath orange

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min. = IEC 331). Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 °C is approximately 4,5 times higher than at 20 °C and the current carrying capacity has to be reduced respectively.

p/nr. Part name Availability Packaging EUR netto pre-metal per 1.000
013312 NHXCH E90 02X2,5/2,5 RE OR on request
Stock choose
-
011042 NHXCH E90 03X1,5/1,5 RE OR Stock
Stock choose
-
011043 NHXCH E90 03X2,5/2,5 RE OR Stock
Stock choose
-
011209 NHXCH E90 03X4/4 RE OR Stock
Stock choose
-
011208 NHXCH E90 03X6/6 RE OR on request
Stock choose
-
011207 NHXCH E90 03X10/10 RE OR on request
Stock choose
-
011206 NHXCH E90 03X16/16 OR on request
Stock choose
-
011205 NHXCH E90 03X25/16 OR on request
Stock choose
-
011204 NHXCH E90 03X35/16 OR on request
Stock choose
-
011197 NHXCH E90 03X50/25 RM OR on request
Stock choose
-
011203 NHXCH E90 03X70/35 RM OR on request
Stock choose
-
011213 NHXCH E90 03X95/50 RM OR on request
Stock choose
-
011202 NHXCH E90 03X120/70 RM OR on request
Stock choose
-
011201 NHXCH E90 03X150/70 RM OR on request
Stock choose
-
011200 NHXCH E90 03X185/95 RM OR on request
Stock choose
-
011198 NHXCH E90 03X240/120 RM OR on request
Stock choose
-
010995 NHXCH E90 04X1,5/1,5 RE OR Stock
Stock choose
-
010996 NHXCH E90 04X2,5/2,5 RE OR Stock
Stock choose
-
010997 NHXCH E90 04X4/4 RE OR Stock
Stock choose
-
010987 NHXCH E90 04X6/6 RE OR Stock
Stock choose
-
010994 NHXCH E90 04X10/10 RE OR Stock
Stock choose
-
010998 NHXCH E90 04X16/16 OR Stock
Stock choose
-
010999 NHXCH E90 04X25/16 OR Stock
Stock choose
-
010993 NHXCH E90 04X35/16 OR Stock
Stock choose
-
011000 NHXCH E90 04X50/25 RM OR Stock
Stock choose
-
011001 NHXCH E90 04X70/35 RM OR Stock
Stock choose
-
011002 NHXCH E90 04X95/50 RM OR Stock
Stock choose
-
011003 NHXCH E90 04X120/70 RM OR Stock
Stock choose
-
011004 NHXCH E90 04X150/70 RM OR Stock
Stock choose
-
011005 NHXCH E90 04X185/95 RM OR Stock
Stock choose
-
011006 NHXCH E90 04X240/120 RM OR Stock
Stock choose
-
011749 NHXCH E90 05X4/4 RE OR Stock
Stock choose
-
010988 NHXCH E90 07X1,5/2,5 RE OR Stock
Stock choose
-
011007 NHXCH E90 07X2,5/2,5 RE OR Stock
Stock choose
-
012739 NHXCH E90 10X1,5/2,5 RE OR on request
Stock choose
-
011008 NHXCH E90 12X1,5/2,5 RE OR Stock
Stock choose
-
011009 NHXCH E90 12X2,5/4 RE OR Stock
Stock choose
-
011210 NHXCH E90 24X1,5/6 RE OR Stock
Stock choose
-
011211 NHXCH E90 24X2,5/10 RE OR Stock
Stock choose
-
011212 NHXCH E90 30X1,5/6 RE OR on request
Stock choose
-
011199 NHXCH E90 30X2,5/10 RE OR on request
Stock choose
-

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metall regarding the daily market price.

The offered products of this online shop are aimed at entrepreneurs according to §14 BGB, traders, freelancer and public organisations. There is no sale for consumers.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-289
Fax +49 681 97 11-289