cable with circuit integrity 90 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C min. installation temperature -5 °C cable with VDE-certification cable conform to Low Voltage directive
0110430400500
drum 500 m
Invalid input!
in stock
Price
Price
Price
0110430401000
drum 1000 m
Invalid input!
in stock
Price
Price
Price
0110430402000
drum 2000 m
Invalid input!
on request
Price
Price
Price
0110430400000
cut length
Invalid input!
in stock
Price
Price
Price

Log in to see prices

New here? Register now
0
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0266
Conductor material copper, bare
Conductor construction class 1, from 25 sqmm class 2
Insulation FRNC-compound HI1
Concentric conductor Cu
Sheathing material FRNC-compound HM1
Colour of outer sheath orange
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Fire-resistant VDE 0472-814/IEC 60331-11 (FE 180)
Circuit integrity E90
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -30 - +90 °C
Permitted outer cable temperature, moved, °C -5 °C
Bending radius, fixed installation 12 x Ø
Core identification colours acc. to HD 308; more than 5 cores: numbers
Conductor shape round
Conductor shape (Faber) RE
Number of cores 3
Nominal cross section, sqmm 2.5 mm²
Conductor resistance 7.41 Ohm/km
Ampacity in air (30 °C) 32 A
Cross-section of concentric conductor 2,5
Bending radius, fixed installation 216 mm
outer diameter approx. 17.90 mm
Colour of outer sheath orange
Copper weight (GER) 104
metal base Cu 0 EUR/100 kg
net weight per 1000 410 kg
Unit of measurement metre
VDE yes
Nominal voltage 0,6/1 kV
Sheathing material FRNC-compound
Cable shape round
Halogen-free yes
Oil-resistant no
Colour orange
Conductor construction class 1 = solid
Insulation FRNC-compound

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 /IEC 60331-11 for 180 minutes. Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 °C is approximately 4,5 times higher than at 20 °C and the current carrying capacity has to be reduced respectively.