cable with circuit integrity 30 min cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 max. permitted temperature at conductor 90 °C cable halogen-free cable with VDE-certification cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
015020(N)HXH-O FE180/E30 plus 2X1.5 RE OG
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
015021(N)HXH-O FE180/E30 plus 2X2.5 RE OG
on request
AufmachungPreis
015022(N)HXH-O FE180/E30 plus 2X4 RE OG
on request
AufmachungPreis
015023(N)HXH-O FE180/E30 plus 2X6 RE OG
on request
AufmachungPreis
015024(N)HXH-O FE180/E30 plus 2X10 RE OG
on request
AufmachungPreis
015025(N)HXH-J FE180/E30 plus 3X1.5 RE OG
in stock
AufmachungPreis
015026(N)HXH-J FE180/E30 plus 3X2.5 RE OG
in stock
AufmachungPreis
015027(N)HXH-J FE180/E30 plus 3X4 RE OG
in stock
AufmachungPreis
015028(N)HXH-J FE180/E30 plus 3X6 RE OG
on request
AufmachungPreis
015029(N)HXH-J FE180/E30 plus 3X10 RE OG
in stock
AufmachungPreis
015030(N)HXH-J FE180/E30 plus 4X1.5 RE OG
in stock
AufmachungPreis
015031(N)HXH-J FE180/E30 plus 4X2.5 RE OG
on request
AufmachungPreis
015032(N)HXH-J FE180/E30 plus 4X6 RE OG
in stock
AufmachungPreis
015033(N)HXH-J FE180/E30 plus 4X10 RE OG
on request
AufmachungPreis
015034(N)HXH-J FE180/E30 plus 5X1.5 RE OG
in stock
AufmachungPreis
015035(N)HXH-J FE180/E30 plus 5X2.5 RE OG
in stock
AufmachungPreis
015036(N)HXH-J FE180/E30 plus 5X4 RE OG
in stock
AufmachungPreis
015037(N)HXH-J FE180/E30 plus 5X6 RE OG
in stock
AufmachungPreis
015038(N)HXH-J FE180/E30 plus 5X10 RE OG
on request
AufmachungPreis
015039(N)HXH-J FE180/E30 plus 7X1.5 RE OG
in stock
AufmachungPreis
015040(N)HXH-J FE180/E30 plus 7X2.5 RE OG
on request
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0266
Conductor material copper, bare
Conductor construction Class 1 = solid
Insulation FRNC-compound HI1
Sheathing material FRNC-compound HM1
Colour of outer sheath orange
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Fire-resistant VDE 0472-814/IEC 60331-11 (FE 180)
Circuit integrity E30
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -5 - +70 °C
Bending radius, fixed installation 12 x Ø
Conductor shape (Faber) RE
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30).

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator