flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 max. permitted temperature at conductor 90 °C cable halogen-free screened cable installation in free air without UV-protection (cable UV-resistant) cable with EAC-approval
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
035325Faber® EMV 2XSL(St)CH-JB 3X16 + 3G2.5 0.6/1 kV BK
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
035663Faber® EMV 2XSL(St)CH-JB 3X25 + 3G4 0.6/1 kV BK
on request
AufmachungPreis
035664Faber® EMV 2XSL(St)CH-JB 3X35 + 3G6 0.6/1 kV BK
on request
AufmachungPreis
035665Faber® EMV 2XSL(St)CH-JB 3X50 + 3G10 0.6/1 kV BK
on request
AufmachungPreis
035520Faber® EMV 2XSL(St)CH-JB 3X70 + 3G10 0.6/1 kV BK
on request
AufmachungPreis
035521Faber® EMV 2XSL(St)CH-JB 3X95 + 3G16 0.6/1 kV BK
on request
AufmachungPreis
035666Faber® EMV 2XSL(St)CH-JB 3X120 + 3G16 0.6/1 kV BK
on request
AufmachungPreis
035657Faber® EMV 2XSL(St)CH-JB 3X150+ 3G25 0.6/1 kV BK
on request
AufmachungPreis
036639Faber® EMV 2XSL(St)CH-JB 3X185 + 3G25 0.6/1 kV BK
on request
AufmachungPreis
035667Faber® EMV 2XSL(St)CH-JB 3X185 + 3G35 0.6/1 kV BK
on request
AufmachungPreis
035668Faber® EMV 2XSL(St)CH-JB 3X240 + 3G50 0.6/1 kV BK
on request
AufmachungPreis
035659Faber® EMV 2XSL(St)CH-JB 4X1.5 0.6/1 kV BK
on request
AufmachungPreis
035254Faber® EMV 2XSL(St)CH-JB 4X2.5 0.6/1 kV BK
on request
AufmachungPreis
035660Faber® EMV 2XSL(St)CH-JB 4X4 0.6/1 kV BK
on request
AufmachungPreis
035661Faber® EMV 2XSL(St)CH-JB 4X6 0.6/1 kV BK
on request
AufmachungPreis
035662Faber® EMV 2XSL(St)CH-JB 4X10 0.6/1 kV BK
on request
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation XLPE
Screen aluminium foil + tinned copper braid
Sheathing material FRNC-compound HM1
Colour of outer sheath black
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
UV-resistant yes
Ozone-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -5 - +90 °C
Permitted outer cable temperature, moved, °C -5 - +90 °C
Bending radius, fixed installation 10 x Ø
Bending radius, moving application 20 x Ø
Core identification colours acc. to VDE 0293 (HD308)
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Halogen-free and flame-retardant cable connecting motors to inverse rectifiers under consideration of EMC-requirements. It may be used under medium mechanical stress for fixed installations and temporary movement. Also for outdoor installation, but not for direct burial.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator