flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 max. permitted temperature at conductor 90 °C cable halogen-free screened cable cable suitable for direct burial installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
037165EMV 2XSL(ST)CHV-JB DB 3X1.5+3G0.25 0.6/1KV BK
in stock
Aufmachung

Log in to see prices

New here? Register now
Preis
036964EMV 2XSL(St)CHv-JB 3X2.5 + 3G0.5 0.6/1 kV BK DB
in stock
AufmachungPreis
036965EMV 2XSL(St)CHv-JB 3X4 + 3G0.75 0.6/1 kV BK DB
in stock
AufmachungPreis
037166EMV 2XSL(ST)CHV-JB DB 3X6+3G1 0.6/1KV BK
in stock
AufmachungPreis
036966EMV 2XSL(St)CHv-JB 3X10 + 3G1.5 0.6/1 kV BK DB
in stock
AufmachungPreis
037167EMV 2XSL(ST)CHV-JB DB 3X16+3G2.5 0.6/1KV BK
in stock
AufmachungPreis
037168EMV 2XSL(ST)CHV-JB DB 3X25+3G4 0.6/1KV BK
in stock
AufmachungPreis
037169EMV 2XSL(ST)CHV-JB DB 3X35+3G6 0.6/1KV BK
on request
AufmachungPreis
037170EMV 2XSL(ST)CHV-JB DB 3X50+3G10 0.6/1KV BK
in stock
AufmachungPreis
037171EMV 2XSL(ST)CHV-JB DB 3X70+3G10 0.6/1KV BK
on request
AufmachungPreis
036967EMV 2XSL(ST)CHV-JB DB 3X95+3G16 0.6/1KV BK
in stock
AufmachungPreis
036968EMV 2XSL(St)CHv-JB 3X120 + 3G16 0.6/1 kV BK DB
in stock
AufmachungPreis
037172EMV 2XSL(ST)CHV-JB DB 3X150+3G25 0.6/1KV BK
in stock
AufmachungPreis
037173EMV 2XSL(ST)CHV-JB DB 3X185+3G35 0.6/1KV BK
in stock
AufmachungPreis
037174EMV 2XSL(ST)CHV-JB DB 3X240+3G50 0.6/1KV BK
in stock
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
CPR-classification according to EN 50575 Dca
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation XLPE
Arrangement of protective conductors split in the outer interstices
Screen aluminium foil + tinned copper braid
Screen coverage 80 %
Sheathing material FRNC-compound ST8
Colour of outer sheath black
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
UV-resistant yes
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -40 - +90 °C
Permitted outer cable temperature, moved, °C -5 - +90 °C
Core identification colours acc. to VDE 0293 (HD308)
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

Halogen-free and flame-retardant cable connecting motors to inverse rectifiers under consideration of EMC-requirements. It may be used under medium mechanical stress for fixed installations and temporary movement. Suitable for indoor and outdoor installation as well as for direct ground burial.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator