flame retardant acc. IEC 60332-1-2 cable halogen-free not for application in power circuits cable suitable for drag-chains installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive
0371840400500
drum 500 m
Invalid input!
on request
Price
Price
Price
0371840401000
drum 1000 m
Invalid input!
on request
Price
Price
Price
0371840400000
cut length
Invalid input!
on request
Price
Price
Price

Log in to see prices

New here? Register now
0
Customs Tariff Number (code number) 85444995900000000
Conductor material copper, bare
Conductor construction Class 6 = very flexible
Insulation TPE
Screen copper braid
Screen coverage 85 %
Sheathing material polyurethan
Colour of outer sheath grey
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -20 - +80 °C
Insulation resistance 20 MOhmxkm
Specific inductivity 0.65 mH/km
Transfer impedance 250 Ohm/km
Core identification colours acc. to DIN 47100
Number of cores 8
Nominal cross section, sqmm 0.5 mm²
outer diameter approx. 8.00 mm
Copper weight (GER) 64
metal base Cu 150 EUR/100 kg
For use in drag chains yes
net weight per 1000 92 kg
Unit of measurement metre
Sheathing material polyurethan
Halogen-free no
Oil-resistant no
Colour black
Insulation TPE

High-flexible and low-capacity data cable for continuous mobile use under extreme conditions with particular requirements on EMC. The cable is halogen-free, flame resistant, hydrolysis- and microbe-resistant and largely oil-resistant. Please note our instructions for the use of drag-chain cables.

All images shown here are for illustrations and product reference purposes only.

Contact
Cable calculator