flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free cable to a large extent oil resistant max. permitted temperature at conductor 90 °C min. installation temperature -35 °C installation in free air only with UV-protection (cable not UV-resistant) cable conform to Low Voltage directive

flame retardant acc. IEC 60332-3-24flame retardant acc. IEC 60332-3-24

cable with low smoke IEC 61034cable with low smoke IEC 61034

cable halogen-freecable halogen-free

cable to a large extent oil resistantcable to a large extent oil resistant

max. permitted temperature at conductor 90 °Cmax. permitted temperature at conductor 90 °C

min. installation temperature -35 °Cmin. installation temperature -35 °C

installation in free air only with UV-protection (cable not UV-resistant)installation in free air only with UV-protection (cable not UV-resistant)

cable conform to Low Voltage directivecable conform to Low Voltage directive

  • Item list
  • Technical data
  • Application
  • Technical documents
Conductor material tinned copper
Conductor class class 5 = fine stranded
Insulation cross-linked polyolefin-copolymer
Sheathing material cross-linked rubber blend
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Oil-resistant EN 60811-2-1
Ozone-resistant DIN EN 60811-2-1(A)
Maximum permitted conductor temperature 90 °C
Permitted outer cable temperature, fixed -60 - +90 °C
Permitted outer cable temperature, in motion/during installation -35 - +90 °C
Bending radius, fixed installation 4 x DA
Bending radius, moving application 6 x DA
Nominal voltage Uo 3600 V
Nominal voltage U 6000 V
Test voltage 11 kV
Number of cores 1
Nominal cross section 10 mm² , 185 mm² , 2.5 mm² , 240 mm² , 25 mm² , 4 mm² , 6 mm² , 95 mm²
Conductor resistance 0.0817 Ohm/km , 0.108 Ohm/km , 0.21 Ohm/km , 0.795 Ohm/km , 1.95 Ohm/km , 3.39 Ohm/km , 5.09 Ohm/km , 8.21 Ohm/km
Ampacity in air (30 °C) 107 A , 195 A , 45 A , 464 A , 60 A , 719 A , 76 A , 845 A
Conductor class class 5 = fine stranded
Outer diameter approx. 10.9 mm , 18.3 mm , 24.6 mm , 27.6 mm , 4.9 mm , 5.7 mm , 6.3 mm , 7.5 mm
Tensile strength (during installation) 1425 N , 150 N , 2775 N , 3600 N , 375 N , 38 N , 60 N , 90 N
Copper weight (GER) 1776 kg/km , 2304 kg/km , 24 kg/km , 240 kg/km , 38,4 kg/km , 58 kg/km , 912 kg/km , 96 kg/km

This insulated wire is designed for application in busses and rail-borne vehicles. If used in distribution or switching appliances up to 1000 V, it is considered to be short circuit-proof. The cable is halogen-free, flame-retardant and resistant to most oils and grease.

p/nr. Part name Availability Packaging EUR netto pre-metal per 1.000
040849 FABER 9GKW-SC PLUS 01X2,5 3,6/6 kV SW on request
Stock choose
-
040848 FABER 9GKW-SC PLUS 01X4 3,6/6 kV SW on request
Stock choose
-
040850 FABER 9GKW-SC PLUS 01X6 3,6/6 kV SW on request
Stock choose
-
040853 FABER 9GKW-SC PLUS 01X10 3,6/6 kV SW on request
Stock choose
-
040851 FABER 9GKW-SC PLUS 01X25 3,6/6 kV SW on request
Stock choose
-
040874 FABER 9GKW-SC PLUS 01X95 3,6/6 kV SW on request
Stock choose
-
040854 FABER 9GKW-SC PLUS 01X185 3,6/6 kV SW on request
Stock choose
-
040846 FABER 9GKW-SC PLUS 01X240 3,6/6 kV SW on request
Stock choose
-

All images shown here are for illustrations and product reference purposes only.

The offered products of this online shop are aimed at entrepreneurs according to §14 BGB, traders, freelancer and public organisations. There is no sale for consumers.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-289
Fax +49 681 97 11-289