min. installation temperature -25 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive cable to a large extent oil resistant flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable for reeling application monospiral reeling cylindric drum
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
052389(N)SSHCGEOEU 3X16+3X(1.5ST KON+10/3 KON) YE
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
0523043X25+3X(1.5 ST KON+16/3 KON) 0.6/1KV YE
in stock
AufmachungPreis
0528303X35+3X(1.5 ST KON+16/3 KON) 0.6/1KV YE
on request
AufmachungPreis
051495NSSHCGEOEU (S) 3X35/16KON+3X(1.5ST KON/1.5UEL KON) YE
on request
AufmachungPreis
Standard VDE 0250-812 (with reference to)
Conductor construction class "FS" = exceptionally fine stranded
Insulation rubber 3GI3
Arrangement of protective conductors split in the outer interstices
Material inner sheath rubber GM1b
Self-supporting element aramide
Torsion protection synthetic braid
Torsion +/- 50 °/m
Sheathing material rubber (CR) 5GM5
Colour of outer sheath yellow
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
Oil-resistant EN 60811-404
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -25 - +60 °C
Bending radius, fixed installation 4 x Ø
Bending radius, moving application 12 x Ø
Maximum tensile strength at the conductor 30 N/mm²
Operating speed 160 m/min.
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

Reeling mining cable for frequently changing dynamic loads and simultaneous tensile and torsional loads. The outer sheath is very resistant to abrasion and tearing.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator