screened cable cable to a large extent oil resistant festoon cable max. permitted temperature at conductor 90 °C min. installation temperature -35 °C installation in free air without UV-protection (cable UV-resistant) cable with VDE-certification
0532500400500
drum 500 m
Invalid input!
on request
Price
Price
Price
0532500401000
drum 1000 m
Invalid input!
on request
Price
Price
Price
0532500400000
cut length
Invalid input!
in stock
Price
Price
Price

Log in to see prices

New here? Register now
0
Customs Tariff Number (code number) 85444995900000000
Standard DIN VDE 0250-809, UL File E 113314
Conductor material copper, bare
Conductor construction class 6 = extra finely stranded, up from 35 sqmm class 5
Insulation rubber 3GI3
Sheathing material Gummi 5GM3
Colour of outer sheath black
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -50 - +80 °C
Permitted outer cable temperature, moved, °C -35 - +80 °C
Bending radius, fixed installation 4 x Ø
Bending radius, moving application 5 x Ø
Maximum tensile strength at the conductor 15 N/mm²
Operating speed festoon, m/min. 180 m/min.
Nominal voltage Uo 300 V
Nominal voltage U 500 V
Core identification colours acc. to HD 308; more than 5 cores: numbers
Number of cores 14
Nominal cross section, sqmm 1 mm²
Conductor resistance 19.5 Ohm/km
Ampacity in air (30 °C) 19 A
Width 56 mm
Height 11.3 mm
Copper weight (GER) 447
metal base Cu 150 EUR/100 kg
net weight per 1000 1106 kg
Unit of measurement metre
crane cables / hoist cables yes
UL/CSA yes
Nominal voltage 300/500 V
Sheathing material rubber
Cable shape flat
Halogen-free no
Oil-resistant yes
Colour black
Conductor construction class 6 = extra finely stranded
Insulation rubber

Screened Power and control cable for high mechanical requirements, frequently bendings in only one direction, especially for use in trolley systems on moving parts of machines and crans. Suitable for dry, humid and wet rooms and for outdoor use combined with specific EMC (electromagnetic compatibility) requirements.

All images shown here are for illustrations and product reference purposes only.