flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable to a large extent oil resistant festoon cable min. installation temperature -25 °C installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
053129(N)GRDGOEU-J 1X70 0.6/1KV BK
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
053130(N)GRDGOEU-J 1X120 0.6/1KV BK
on request
AufmachungPreis
0528991X150 0.6/1 kV BK
on request
AufmachungPreis
0530353G25 0.6/1 KV BK
on request
AufmachungPreis
0530363G35 0.6/1 KV BK
on request
AufmachungPreis
0530373G50 0.6/1 KV BK
on request
AufmachungPreis
0530383G70 0.6/1 KV BK
on request
AufmachungPreis
0529004X4 0.6/1 kV BK
on request
AufmachungPreis
0529014X6 0.6/1 kV BK
on request
AufmachungPreis
0530394G10 0.6/1 KV BK
on request
AufmachungPreis
0529024X10 0.6/1 kV BK
on request
AufmachungPreis
0529034G35 0.6/1 kV BK
on request
AufmachungPreis
053131(N)GRDGOEU-J 5G6 0.6/1KV BK
on request
AufmachungPreis
053132(N)GRDGOEU-J 5G10 0.6/1KV BK
on request
AufmachungPreis
0529045X10 0.6/1 kV BK
on request
AufmachungPreis
053115(N)GRDGOEU-J 5G25 0.6/1KV BK
on request
AufmachungPreis
053133(N)GRDGOEU-J 24G1.5 0.6/1KV BK
on request
AufmachungPreis
05304012G2.5 0.6/1 KV BK
on request
AufmachungPreis
05290512X2.5 0.6/1 kV BK
on request
AufmachungPreis
05290618G2,5 0.6/1 kV BK
on request
AufmachungPreis
053117(N)GRDGOEU-J 24G2.5 0.6/1KV BK
on request
AufmachungPreis
053118(N)GRDGOEU-J 30G2.5 0.6/1KV BK
on request
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Standard DIN VDE 0250-814 (with ref. to)
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Material inner sheath rubber GM1b
Torsion +/- 90 °/m
Sheathing material rubber (CR) 5GM3
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant VDE 0473-811-404/IEC 60811-404
Ozone-resistant VDE 0473-811-403/IEC 60811-403
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, moved, °C -25 - +80 °C
Bending radius, moving application 5 x Ø
Maximum tensile strength at the conductor 15 N/mm²
Operating speed festoon, m/min. 240 m/min.
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Power and control cables suitable for connection wagons of cranes (festoones), conveyor systems, moved parts of machine tools etc. Due to the good UV- and ozone-resistance they may be used indoors and outdoors.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact