flame retardant acc. IEC 60332-1-2 cable to a large extent oil resistant cable suitable for drag-chains max. permitted temperature at conductor 90 °C cable for reeling application min. installation temperature -25 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with UL/CSA-certification
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
054281BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X25/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

Presentation

Log in to see prices

New here? Register now
Price
054282BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X35/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054283BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X50/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054284BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X70/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054285BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X95/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054286BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X120/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054287BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X150/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054288BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X185/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054289BITFLEX DC (N)TMCGCWOEU UL 6/10KV 1X240/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054290BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X25/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054291BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X35/16 RD
in stock
PresentationPrice
054292BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X50/16 RD
in stock
PresentationPrice
054293BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X70/16 RD
in stock
PresentationPrice
054294BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X95/16 RD
in stock
PresentationPrice
054295BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X120/16 RD
in stock
PresentationPrice
054296BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X150/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054297BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X185/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054298BITFLEX DC (N)TMCGCWOEU UL 12/20KV 1X240/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
055127BITFLEX DC (N)TMCGCWOEU UL 18/30KV 01X95/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
055100BITFLEX DC (N)TMCGCWOEU UL 18/30KV 1X120/16 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054830BITFLEX DC (N)TMCGCWOEU UL 18/30KV 1X150/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054862BITFLEX DC (N)TMCGCWOEU UL 18/30KV 1X185/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
054856BITFLEX DC (N)TMCGCWOEU UL 18/30KV 1X240/25 RD
MOQ

MOQ: 1000

Delivery time: approx. 23W

PresentationPrice
Customs Tariff Number (code number) 85446010900
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation basic EPR
Electrical field control inner and outer semiconducting rubber layer
Arrangement of protective conductors spirally applied tinned copper wires
Screen coverage, approx. 86 %
Sheathing material rubber 5GM5
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
Water-resistant AD8
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 200 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -25 - +80 °C
Min. bending radius, fixed installation 6 x Ø
Bending radius, moving application 8 x Ø
Maximum tensile strength at the conductor 15 N/mm²
Number of cores 1
outer diameter min. 39 mm
outer diameter max. 42 mm
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

Flexible medium voltage cable for use in offshore power systems, particularly in slow-running energy chains, drum applications, or for supplying power to large electrical systems and drives through energy management systems. The cable can be used in locations where it is completely submerged in water and permanently subjected to a pressure of more than 1 bar up to a maximum of 10 bar (Protection Class AD8).

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator