installation in free air without UV-protection (cable UV-resistant) cable to a large extent oil resistant max. permitted temperature at conductor 90 °C flame retardant acc. IEC 60332-1-2 min. installation temperature -30 °C
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
0528701x95/16 6/10 kV
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
0528711x120/16 6/10 kV
on request
AufmachungPreis
0528721x150/25 6/10 kV
on request
AufmachungPreis
0528731x185/25 6/10 kV
on request
AufmachungPreis
0529291x240/25 6/10 kV
on request
AufmachungPreis
0528831x300/25 6/10 kV
on request
AufmachungPreis
0528841x500/35 6/10 kV
on request
AufmachungPreis
053151BITMINING (N)TMCGCWOEU 8.7/15KV 1X400/35 RD
on request
AufmachungPreis
0529131x35/16 12/20 kV
on request
AufmachungPreis
0529141x50/16 12/20 kV
on request
AufmachungPreis
0529151x70/16 12/20 kV
on request
AufmachungPreis
0529161x95/16 12/20 kV
on request
AufmachungPreis
0529171x120/16 12/20 kV
on request
AufmachungPreis
0529181x150/25 12/20 kV
on request
AufmachungPreis
0529191x185/25 12/20 kV
on request
AufmachungPreis
0528741x240/25 12/20 kV
on request
AufmachungPreis
0528801x300/25 12/20 kV
on request
AufmachungPreis
052875500/35 12/20 kV
on request
AufmachungPreis
052935BITMINING (N)TMCGCWOEU 18/30KV 1X50/16 RD
on request
AufmachungPreis
053103BITMINING (N)TMCGCWOEU 18/30KV 1X300/25 RD
on request
AufmachungPreis
052925400/35 18/30 kV
on request
AufmachungPreis
052979500/35 18/30 kV
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation basic EPR
Electrical field control inner and outer semiconducting rubber layer
Sheathing material rubber 5GM5
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 200 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -25 - +80 °C
Bending radius, fixed installation 6 x Ø
Bending radius, moving application 10 x Ø
Maximum tensile strength at the conductor 15 N/mm²
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

Single core cables are used in short lengths, e.g. for the connection of switchgear cubicles and for the connection of mobile transformer substations. When laying and during operation, care should be taken to protect them from excessive mechanical stress. The outer semi-conducting layer must not be heated before removal.

All images shown here are for illustrations and product reference purposes only.