flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C min. installation temperature +5 °C installation in free air without UV-protection (cable UV-resistant) cable with EAC-approval
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
054272FABER (N)3GHSSYCY 3X50+3X25/3E+3X2.5+UEL 10KV RD
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
054036FABER (N)3GHSSYCY 3X95+3X50/3E+3X2.5+UEL 6KV RD
on request
AufmachungPreis
054018FABER (N)3GHSSYCY 3X70+3X35/3E+3X2.5+UEL 10KV RD
on request
AufmachungPreis
0536673X120 + 3X70/3E + 3X2.5 + UEL KON 6/10 kV RD
on request
AufmachungPreis
0527803X25+3X16/3E+3X2.5+UEL KON 12/20 kV RD
on request
AufmachungPreis
0523593X35+3X16/3E+3X2.5+UEL KON 12/20 kV RD
in stock
AufmachungPreis
0524293X50+3X25/3E+3X2.5+UEL KON 12/20 kV RD
in stock
AufmachungPreis
0529763X70+3X35/3E+3X2.5+UEL KON 12/20 kV RD
on request
AufmachungPreis
0524303X95+3X50/3E+3X2.5+UEL KON 12/20 kV RD
in stock
AufmachungPreis
0529583X120+3X70/3E+3X2.5+UEL KON 12/20 kV RD
on request
AufmachungPreis
0528693X150+3X70/3E+3X2.5+UEL KON 12/20 kV RD
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-605 & IEC 60502-2 (with ref. to)
Specification/Standard DIN VDE 0250-605 & IEC 60502-2 (in Anlehnung/ with reference to)
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Electrical field control inner and outer semiconducting rubber layer
Pilot conductor split in the outer interstices
Core wrapping plastic foil
Arrangement of protective conductors tinned copper wire braid over each phase
Material inner sheath PVC YM5
Monitoring core copper wire spinning on first inner sheath
Armour steel wire braid, galvanized, min. corverage 75%
Torsion +/- 25 °/m
Sheathing material PVC DMV6
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C 5 - 80 °C
Bending radius, fixed installation 5 x Ø
Bending radius, moving application 10 x Ø
Maximum tensile strength at the conductor 20 N/mm²
Operating speed 30 m/min.
Insulation wall thickness 3.5 mm
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

As power supply cable for mobile MV equipment in mining and tunnel applications.