flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C min. installation temperature -25 °C installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
053493FABER MINING F-(N)TSCGEWOEU 3X25+3X25/3 6/10KV RD
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
053438FABER MINING F-(N)TSCGEWOEU 3X35+3X25/3 6/10KV RD
on request
AufmachungPreis
053496FABER MINING F-(N)TSCGEWOEU 3X35+3X25/3 20KV RD
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation basic EPR
Electrical field control inner and outer semiconducting rubber layer
Arrangement of protective conductors split in the outer interstices
Material inner sheath rubber GM1b
Torsion +/- 100 °/m
Sheathing material rubber 5GM5
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -25 - +80 °C
Bending radius, fixed installation 6 x Ø
Bending radius, moving application 10 x Ø
Maximum tensile strength at the conductor 15 N/mm²
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Flexible cable for fixed energy distribution lines in opencast minings, alongside conveyor systems, connection cables for transformers or bucket wheel excavators.

- Min. bending radius: acc. to VDE 0298-3
- Max. current rating: acc. to VDE 0298-4

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator