flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable to a large extent oil resistant cable for reeling application installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
0529313X35+3X25/3E+3X2.5ST+6 UEL KON 12/20 kV RD
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
0529633X25+3X16/3E+3X2.5ST+6 UEL KON 6/10 kV RD
on request
AufmachungPreis
0529643X35+3X25/3E+3X2.5ST+6 UEL KON 6/10 kV RD
on request
AufmachungPreis
0529653X50+3X25/3E+3X2.5ST+6 UEL KON 6/10 kV RD
on request
AufmachungPreis
053699KF TBM (N)TSCGECWHOEU 3X70+3X35/3E+ 6/10KV RD
on request
AufmachungPreis
054035KF TBM (N)TSCGECWHOEU 3X120+3X70/3E+ 6/10KV RD
on request
AufmachungPreis
0529323X50+3X25/3E+3X2.5ST+6 UEL KON 12/20 kV RD
on request
AufmachungPreis
0529773X70+3X35/3E+3X2.5ST+6 UEL KON 12/20 kV RD
on request
AufmachungPreis
053822KF TBM (N)TSCGECWHOEU 3X120+3X70/3E+ 12/20KV RD
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Electrical field control inner and outer semiconducting rubber layer
Pilot conductor tinned copper conductors, rubber 3GI3, with semi-conductive layer, splitted into three parts in the outer interstices
Arrangement of protective conductors mixed braid of tinned copper wires and textile fibers over each core
Material inner sheath rubber GM1b
Monitoring core Copper wire over the inner sheath
Torsion +/- 25 °/m
Sheathing material polyurethan
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -20 - +60 °C
Min. distance with S-type diretional changes 20 x Ø
Operating speed 30 m/min.
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

Flexible cable suitable for reeling drum of tunnel boring machines (TBM) and generally for tunnel application. Other applications have to be agreed with Faber Kabel, otherwise warranty may get lost.

Bending radius: acc. to DIN VDE 0298-3

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact