flame retardant acc. IEC 60332-1-2 cable halogen-free cable to a large extent oil resistant max. permitted temperature at conductor 90 °C cable for reeling application installation in free air without UV-protection (cable UV-resistant) cable with EAC-approval
0535910400500
drum 500 m
Invalid input!
MOQ

MOQ: 1 km

Delivery time: approx. 34 weeks

Price
Price
Price
0535910401000
drum 1000 m
Invalid input!
MOQ

MOQ: 1 km

Delivery time: approx. 34 weeks

Price
Price
Price
0535910400000
cut length
Invalid input!
MOQ

MOQ: 1 km

Delivery time: approx. 34 weeks

Price
Price
Price

Log in to see prices

New here? Register now
0
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Electrical field control inner and outer semiconducting rubber layer
Pilot conductor tinned copper conductors, rubber 3GI3, with semi-conductive layer, splitted into three parts in the outer interstices
Arrangement of protective conductors mixed braid of tinned copper wires and textile fibers over each core
Material inner sheath rubber GM1b
Monitoring core Copper wire over the inner sheath
Torsion +/- 25 °/m
Sheathing material special EVA based halogen free rubber compound
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
Halogen-free DIN EN 50267/IEC 60754
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -20 - +60 °C
Min. distance with S-type diretional changes 20 x Ø
Operating speed 30 m/min.
Number of cores 3
Nominal cross section, sqmm 50 mm²
outer diameter approx. 55.80 mm
Copper weight (GER) 1893
metal base Cu 150 EUR/100 kg
net weight per 1000 4140 kg
Unit of measurement metre
crane cables / hoist cables yes
GOST/EAC yes
Nominal voltage 6/10 kV
Sheathing material rubber
Cable shape round
Halogen-free yes
Oil-resistant yes
Colour red
Conductor construction class 5 = fine stranded
Insulation rubber

Flexible cable suitable for reeling drum of tunnel boring machines (TBM) and generally for tunnel application. Other applications have to be agreed with Faber Kabel, otherwise warranty may get lost.

Bending radius: acc. to DIN VDE 0298-3

All images shown here are for illustrations and product reference purposes only.

Contact