3x50 + 2x25/2 + 1x(12G62.5/125) 8.7/15 kV RD
Your p/nr.
MOQ
MOQ: 500 m
Delivery time: approx. 34 weeks
MOQ
MOQ: 500 m
Delivery time: approx. 34 weeks
MOQ
MOQ: 500 m
Delivery time: approx. 34 weeks
Customs Tariff Number (code number) | 85446010900000000 |
Standard | DIN VDE 0250-813 (with ref. to) |
Conductor material | copper, bare |
Conductor construction | Class 5 = flexible |
Insulation | rubber (EPR) 3GI3 |
Electrical field control | inner and outer semiconducting rubber layer |
Arrangement of protective conductors | split in the outer interstices |
Material inner sheath | Gummi 5GM3 |
Torsion protection | synthetic braid |
Sheathing material | rubber 5GM5 |
Colour of outer sheath | red |
UV-resistant | yes |
Oil-resistant | EN 60811-404 |
Ozone-resistant | yes |
Max. temperature at conductor, °C | 90 °C |
Max. short circuit temperature at conductor, °C | 250 °C |
Permitted outer cable temperature, fixed, °C | -40 - +80 °C |
Permitted outer cable temperature, moved, °C | -25 - +80 °C |
Operating speed monospiral (two ways), m/min. | 160 m/min. |
Operating speed monospiral (one way), m/min. | 200 m/min. |
Number of cores | 3 |
Nominal cross section, sqmm | 50 mm² |
Conductor resistance | 0.38600000000000001 Ohm/km |
Ampacity in air (30 °C) | 215 A |
Short-circuit current (1 s) | 7.15 kA |
outer diameter approx. | 48.50 mm |
Tensile strength (permanent) | 3000 N |
Tensile strength (dynamic) | 3750 N |
Copper weight (GER) | 1680 |
metal base Cu | 150 EUR/100 kg |
net weight per 1000 | 3640 kg |
Unit of measurement | metre |
Nominal voltage | 8,7/15 kV |
Sheathing material | rubber |
Cable shape | round |
Halogen-free | no |
Oil-resistant | yes |
Colour | red |
Conductor construction | class 5 = fine stranded |
Insulation | rubber |
Flexible medium voltage reeling cable with fiber optic wires, for high and extreme mechanical stress, e.g. torsional stress, deflection and high reeling speed. Other applications have to be agreed with Faber otherwise warranty may become void. The cables can be manufactured to order or project-specific with E9/125, 50/125 or 62.5/125 fibres.
- Min. bending radius: acc. to VDE 0298-3
- Max. Current carrying capacity: acc. to VDE 0298-4 table 15
All images shown here are for illustrations and product reference purposes only.