installation in free air without UV-protection (cable UV-resistant) cable to a large extent oil resistant flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable for reeling application monospiral reeling cylindric drum min. installation temperature -30 °C
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
0525943X25 + 3X25/3 3.6/6 kV RD
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
0525953X35+3X25/3 3.6/6KV RD
on request
AufmachungPreis
0525963X5 + 3X25/3 3.6/6 kV RD
on request
AufmachungPreis
053790URSUS MT KN PLUS 3X95+3X50/3 3.6/6KV RD
on request
AufmachungPreis
0525973X25 + 3X25/3 6/10 kV RD
on request
AufmachungPreis
0525983X35 + 3X25/3 6/10 kV RD
on request
AufmachungPreis
0525993X50 + 3X25/3 6/10 kV RD
on request
AufmachungPreis
0530023X70 + 3X35/3 6/10 kV RD
on request
AufmachungPreis
054490URSUS MT KN PLUS 3X95+3X50/3 6/10KV RD
on request
AufmachungPreis
0526003X25 + 3X25/3 8.7/15 kV RD
on request
AufmachungPreis
0526013X35 + 3X25/3 8.7/15 kV RD
on request
AufmachungPreis
0526023X50 + 3X25/3 8.7/15 kV RD
on request
AufmachungPreis
0526033X25 + 3X25/3 12/20 kV RD
on request
AufmachungPreis
0525903X35 + 3X25/3 12/20 kV RD
in stock
AufmachungPreis
0526043X50 + 3X25/3 12/20 kV RD
in stock
AufmachungPreis
053383URSUS MT KN PLUS 3X240+3X120/3 12/20KV RD
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Electrical field control inner and outer semiconducting rubber layer
Central filler semiconductive compound on Kevlar® element
Core wrapping semiconductive tape
Arrangement of protective conductors split in the outer interstices
Material inner sheath rubber Gm1b/5GM5
Torsion protection polyester braid
Torsion +/- 25 °/m
Sheathing material rubber (CR) 5GM5
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C -50 - +80 °C
Permitted outer cable temperature, moved, °C -30 - +80 °C
Maximum tensile strength at the conductor 30 N/mm²
Operating speed 240 m/min.
metal base Cu 150 EUR/100 kg
Reelable yes
Unit of measurement metre
crane cables / hoist cables yes

Flexible medium voltage reeling cable with reduced weight and dimensions, for high and extreme mechanical stress, e.g. torsional stress, deflection and high reeling speed. Other applications have to be agreed with Faber otherwise warranty may become void.
- Min. bending radius: acc. to VDE 0298-3
- Max. current rating: acc. to VDE 0298-4

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator