flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable to a large extent oil resistant cable for reeling application min. installation temperature -20 °C installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
052815PTM (N)TSCGECEWOEU MT 3X35+3X25/3E+ 6/10KV RD
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
052255PTM (N)TSCGECEWOEU MT 3X50+3X25/3E+ 6/10KV RD
on request
AufmachungPreis
051508PTM (N)TSCGECEWOEU MT 3X35+3X25/3E+ 12/20KV RD
on request
AufmachungPreis
053595PTM (N)TSCGECEWOEU MT 3X50+3X25/3E+ 12/20KV RD
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material copper, stranded, tinned
Insulation basic EPR
Electrical field control inner and outer semiconducting rubber layer
Pilot conductor split in the outer interstices
Arrangement of protective conductors copper wires on each core
Material inner sheath rubber GM1b
Monitoring core copper wire spinning on first inner sheath
Torsion +/- 25 °/m
Sheathing material rubber (CR) 5GM5
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
Oil-resistant EN 60811-404
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -20 - +60 °C
Bending radius, fixed installation 6 x Ø
Bending radius, moving application 20 x Ø
Maximum tensile strength at the conductor 15 N/mm²
Operating speed 30 m/min.
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Flexible medium voltage reeling cable for tunnel boring machines (TBM) in underground mining and tunnel construction.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator