cable conform to Low Voltage directive flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C installation in free air only with UV-protection (cable not UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
090375(N)A2XH-O 1X50 RM 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 10 weeks

Presentation

Log in to see prices

New here? Register now
Price
090384(N)A2XH-O 1X70 RM 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 10 weeks

PresentationPrice
090376(N)A2XH-O 1X95 RM 0.6/1 kV BK
MOQ

MOQ: 7 km

Delivery time: approx. 10 weeks

PresentationPrice
090377(N)A2XH-O 1X120 RM 0.6/1 kV BK
MOQ

MOQ: 7 km

Delivery time: approx. 10 weeks

PresentationPrice
090272(N)A2XH-O 1X150 RM 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
090268(N)A2XH-O 1X240 RM 0.6/1 kV BK
MOQ

MOQ: 6 km

Delivery time: approx. 10 weeks

PresentationPrice
090202(N)A2XH-O 1X300 RM 0.6/1 kV BK
MOQ

MOQ: 6 km

Delivery time: approx. 10 weeks

PresentationPrice
090269(N)A2XH-O 1X400 RM 0.6/1 kV BK
MOQ

MOQ: 6 km

Delivery time: approx. 10 weeks

PresentationPrice
090372(N)A2XH-J 4X240 SM 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 10 weeks

PresentationPrice
090355(N)A2XH-J 5X70 SM 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 10 weeks

PresentationPrice
090356(N)A2XH-J 5X95 SM 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 10 weeks

PresentationPrice
090357(N)A2XH-J 5X240 SM 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
Customs Tariff Number (code number) 85446090000000000
Standard VDE 0276-604 (with ref. to)
Conductor material aluminium
Conductor construction Class 2 = stranded
Insulation XLPE 2XI1
Sheathing material FRNC-compound HM4
Colour of outer sheath black
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -30 - +70 °C
Permitted outer cable temperature, moved, °C -5 - +70 °C
metal base Al (ger) 0 EUR/100 kg
Unit of measurement metre

Low-smoke, zero-halogen, flame-retardant power cable. For fixed indoor and outdoor installation as well as in concrete, but not for direct burial in the ground or application in water.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator