flame retardant acc. IEC 60332-1-2 cable suitable for direct burial max. permitted temperature at conductor 90 °C min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingUM_ORDERMATRIX_TYPEGROUP_TABLEHEAD_PRICEBEFOREMETAL_UNIT_
015344N2XY-J 1X150 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 6000

Delivery time: approx. 9W

Presentation

Log in to see prices

New here? Register now
Price
015931N2XY-J 1X120 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
015408N2XY-J 1X185 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx. 9W

PresentationPrice
015409N2XY-J 1X240 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 6000

Delivery time: approx. 9W

PresentationPrice
016086N2XY-J 3X1.5 RE 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
016087N2XY-J 3X2.5 RE 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120997N2XY-J 03X16 RMV 0.6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120226N2XY-J 04X4 RE 0.6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120227N2XY-J 04X6 RE 0.6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120228N2XY-J 04X10 RE 0.6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120229N2XY-J 04X16 RM 0.6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120230N2XY-J 04x25 RM 0.6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120231N2XY-J 04X35 RM 0.6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120232N2XY-J 04X50 SM 0,6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
120233N2XY-J 04X70 SM 0,6/1 kV BK VDE 0276
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
016032N2XY-J 4X95 SM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
016033N2XY-J 4X120 SM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
016089N2XY-J 5X1.5 RE 0.6/1 kV VDE 0276 BK
in stock
PresentationPrice
016090N2XY-J 5X2.5 RE 0.6/1 kV VDE 0276 BK
in stock
PresentationPrice
016116N2XY-J 5X4 RE 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
016117N2XY-J 5X6 RE 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
016118N2XY-J 5X25 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
015889N2XY-O 1X50 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
015890N2XY-O 1X70 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
016035N2XY-O 1X95 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
015566N2XY-O 1X120 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 7000

Delivery time: approx. 9W

PresentationPrice
015894N2XY-O 1X150 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
015410N2XY-O 1X185 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 6000

Delivery time: approx. 9W

PresentationPrice
015411N2XY-O 1X240 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 6000

Delivery time: approx. 9W

PresentationPrice
015345N2XY-O 1X300 RM 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 6000

Delivery time: approx. 9W

PresentationPrice
013201N2XY-O 1X400 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 5000

Delivery time: approx. 9W

PresentationPrice
012468N2XY-O 1X500 0.6/1 kV VDE 0276 BK
MOQ

MOQ: 5000

Delivery time: approx. 9W

PresentationPrice
121320(N)2XY-J 8x1.5 RE 0.6/1 kV BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
121321(N)2XY-J 8x2.5RE 0,6/1 kV BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
121317(N)2XY-J 12x1.5 RE 0.6/1 kV BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
121318(N)2XY-J 12x2.5 RE 0.6/1 kV BK
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
121319(N)2XY-J 14x1.5 RE 0.6/1 kV SW
MOQ

MOQ: 0

Delivery time: approx.

PresentationPrice
Customs Tariff Number (code number) 85444995900
CPR-classification according to EN 50575 Eca
Standard VDE 0276-603
Conductor material copper, bare
Conductor construction Class 2 = stranded
Insulation XLPE
Sheathing material PVC
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C 50 °C
Permitted outer cable temperature, moved, °C -5 - +50 °C
Bending radius, fixed installation, multicore 12 x Ø
Conductor shape round
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For fixed installation indoors, outdoors, in ground and in water.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator