flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 max. permitted temperature at conductor 90 °C cable halogen-free cable suitable for direct burial min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
090506(N)A2XCH 1X120RM/25 0.6/1 kV BK
MOQ

MOQ: 6 km

Delivery time: approx. 10 weeks

Presentation

Log in to see prices

New here? Register now
Price
090507(N)A2XCH 1X185RM/35 0.6/1 kV BK
MOQ

MOQ: 6 km

Delivery time: approx. 10 weeks

PresentationPrice
090540(N)A2XCH 3X70SM/35 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
090541(N)A2XCH 3X95SM/50 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
090542(N)A2XCH 3X240SM/120 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
090508(N)A2XCH 4X70SM/35 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
090509(N)A2XCH 4X150SM/70 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
090410(N)A2XCH 4X185 SM/95 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
090315(N)A2XCH 4X240 SM/120 0.6/1 kV BK
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

PresentationPrice
Customs Tariff Number (code number) 85446090000000000
Standard VDE 0276-604 (with ref. to)
Conductor material aluminium
Conductor construction Class 2 = stranded
Insulation XLPE
Material inner sheath halogen-free
Concentric conductor Cu
Sheathing material FRNC-compound HM4
Colour of outer sheath black
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
UV-resistant yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C -40 - +90 °C
Permitted outer cable temperature, moved, °C -5 - +90 °C
Bending radius, fixed installation, multicore 12 x Ø
metal base Al (ger) 0 EUR/100 kg
metal base Cu 0 EUR/100 kg
Unit of measurement metre

Low-smoke, zero-halogen flame retardant power cable. For fixed installation indoor, outdoor installation as well as in concrete and for direct burial in ground, but not in water.