flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C installation in free air only with UV-protection (cable not UV-resistant) cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
090375(N)A2XH-O 1X50 RM 0.6/1 kV BK
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
090384(N)A2XH-O 1X70 RM 0.6/1 kV BK
on request
AufmachungPreis
090376(N)A2XH-O 1X95 RM 0.6/1 kV BK
on request
AufmachungPreis
090377(N)A2XH-O 1X120 RM 0.6/1 kV BK
on request
AufmachungPreis
090272(N)A2XH-O 1X150 RM 0.6/1 kV BK
on request
AufmachungPreis
090385(N)A2XH-O 1X185 RM 0.6/1 kV BK
on request
AufmachungPreis
090268(N)A2XH-O 1X240 RM 0.6/1 kV BK
on request
AufmachungPreis
090202(N)A2XH-O 1X300 RM 0.6/1 kV BK
on request
AufmachungPreis
090269(N)A2XH-O 1X400 RM 0.6/1 kV BK
on request
AufmachungPreis
090203(N)A2XH-O 1X500 RM 0.6/1 kV BK
on request
AufmachungPreis
090299(N)A2XH-O 1X630 RM 0.6/1 kV BK
on request
AufmachungPreis
090373(N)A2XH-O 4X240 SM 0.6/1 kV BK
on request
AufmachungPreis
090371(N)A2XH-J 1X240 SM 0.6/1 kV BK
on request
AufmachungPreis
090412(N)A2XH-J 4X35 RM/16 RM 0.6/1 kV BK
on request
AufmachungPreis
090413(N)A2XH-J 4X50 RM/16 RM 0.6/1 kV BK
on request
AufmachungPreis
090414(N)A2XH-J 4X95 RM/50 RM 0.6/1 kV BK
on request
AufmachungPreis
090355(N)A2XH-J 5X70 SM 0.6/1 kV BK
on request
AufmachungPreis
090356(N)A2XH-J 5X95 SM 0.6/1 kV BK
on request
AufmachungPreis
090357(N)A2XH-J 5X240 SM 0.6/1 kV BK
on request
AufmachungPreis
Customs Tariff Number (code number) 85446090000000000
Standard VDE 0276-604 (with ref. to)
Conductor material aluminium
Conductor construction Class 2 = stranded
Insulation XLPE 2XI1
Sheathing material FRNC-compound HM4
Colour of outer sheath black
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -30 - +70 °C
Permitted outer cable temperature, moved, °C -5 - +70 °C
metal base Al (ger) 0 EUR/100 kg
Unit of measurement metre

Low-smoke, zero-halogen, flame-retardant power cable. For fixed indoor and outdoor installation as well as in concrete, but not for direct burial in the ground or application in water.

All images shown here are for illustrations and product reference purposes only.