flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable suitable for direct burial min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
012599(N)2XRY-J 3X1.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
012475(N)2XRY-J 3X2.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012476(N)2XRY-J 3X4 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
014827(N)2XRY-J 3X10 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012477(N)2XRY-J 4X2.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012478(N)2XRY-J 4X4 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012479(N)2XRY-J 4X6 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012480(N)2XRY-J 4X10 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012481(N)2XRY-J 4X16 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012600(N)2XRY-J 5X1.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012494(N)2XRY-J 5X2.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
014828(N)2XRY-J 5X4 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012601(N)2XRY-J 5X6 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012602(N)2XRY-J 5X16 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012482(N)2XRY-J 7X2.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
014829(N)2XRY-J 8X2.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
012483(N)2XRY-J 12X2.5 RE 0.6/1 kV BK acc. to VDE 0271
on request
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0271 (with reference to)
Conductor material copper, bare
Conductor construction Class 1 = solid
Insulation XLPE DIX3
Material inner sheath PVC
Armour round steel wire, galvanized
Sheathing material PVC DMV6
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -30 - +70 °C
Permitted outer cable temperature, moved, °C -5 - +70 °C
Bending radius, fixed installation 12 x Ø
Core identification colours acc. to VDE 0293 (HD 308); more than 5 cores: gn-ye + numbers
Conductor shape (Faber) RE
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in the ground, in water, outdoors, indoors and in cable ducts if greater mechanical protection is required.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator