• Sprache wechseln DE
    |
    EN
  • Cart
0 0

NA2X2Y

NA2X2Y
cable suitable for direct burial max. permitted temperature at conductor 90 °C min. installation temperature -20 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with VDE-certification cable conform to Low Voltage directive

cable suitable for direct burialcable suitable for direct burial

max. permitted temperature at conductor 90 °Cmax. permitted temperature at conductor 90 °C

min. installation temperature -20 °Cmin. installation temperature -20 °C

installation in free air without UV-protection (cable UV-resistant)installation in free air without UV-protection (cable UV-resistant)

cable for use in watercable for use in water

cable with VDE-certificationcable with VDE-certification

cable conform to Low Voltage directivecable conform to Low Voltage directive

  • Item list
  • Technical data
  • Application
  • Technical documents
Standard VDE 0276-603
Conductor material aluminium
Conductor class class 2 = stranded
Insulation XLPE
Sheathing material polyethylene
Colour outer sheath black
Flame-retardant no
UV-resistant yes
For outdoor use yes
Maximum permitted conductor temperature 90 °C
Permitted outer cable temperature, fixed -20 - +70 °C
Bending radius, fixed installation 15 x DA
Nominal voltage Uo 600 V
Protective conductor no , yes
Nominal voltage U 1000 V
Maximum permitted operating voltage in three-phase systems 1.2 kV
Test voltage 4 kV
Core identification colours acc. to VDE 0293 (HD308)
Conductor shape (Faber) RE , RMv , SE , SMv
Number of cores 1 , 4
Nominal cross section 120 mm² , 150 mm² , 16 mm² , 185 mm² , 240 mm² , 25 mm² , 300 mm² , 35 mm² , 50 mm² , 500 mm² , 70 mm² , 800 mm² , 95 mm²
Conductor resistance 0.0367 Ohm/km , 0.0605 Ohm/km , 0.1 Ohm/km , 0.125 Ohm/km , 0.164 Ohm/km , 0.206 Ohm/km , 0.253 Ohm/km , 0.32 Ohm/km , 0.443 Ohm/km , 0.641 Ohm/km , 0.869 Ohm/km , 1.2 Ohm/km , 1.91 Ohm/km
Insulation wall thickness 0.8 mm , 0.9 mm , 1 mm , 1.1 mm , 1.2 mm , 1.4 mm , 1.6 mm , 1.7 mm , 1.8 mm , 2.2 mm , 2.5 mm
Ampacity in air (30 °C) 1019 A , 102 A , 126 A , 149 A , 191 A , 234 A , 273 A , 295 A , 311 A , 339 A , 360 A , 395 A , 427 A , 472 A , 547 A , 754 A , 78 A
Ampacity in ground (20 °C) 112 A , 135 A , 158 A , 196 A , 234 A , 268 A , 272 A , 300 A , 305 A , 342 A , 347 A , 398 A , 404 A , 457 A , 601 A , 776 A , 86 A
Short-circuit current (1 s) 1.5 kA , 11.28 kA , 14.1 kA , 17.39 kA , 17.4 kA , 2.35 kA , 22.56 kA , 22.6 kA , 28.2 kA , 3.29 kA , 4.7 kA , 47 kA , 6.58 kA , 75.2 kA , 8.93 kA
Specific inductivity 0.246 mH/km
Wall thickness of sheath 1.8 mm , 1.9 mm , 2 mm , 2.1 mm , 2.2 mm , 2.3 mm , 2.4 mm , 2.6 mm , 2.8 mm
Conductor class class 1 = solid , class 2 = stranded
Outer diameter approx. 19.5 mm , 20 mm , 22 mm , 23.5 mm , 25.5 mm , 26 mm , 27 mm , 27.4 mm , 30.5 mm , 34 mm , 34.3 mm , 37.5 mm , 41.5 mm , 46 mm , 52 mm , 58 mm
Tensile strength (during installation) 11400 N , 14400 N , 15000 N , 18001 N , 1920 N , 22200 N , 24000 N , 28800 N , 3000 N , 3600 N , 4200 N , 4500 N , 5550 N , 6000 N , 7200 N , 8400 N , 9000 N
Aluminium weight (GER) 1102 kg/km , 1392 kg/km , 1450 kg/km , 1740 kg/km , 186 kg/km , 2146 kg/km , 2320 kg/km , 2784 kg/km , 290 kg/km , 348 kg/km , 406 kg/km , 435 kg/km , 536,5 kg/km , 580 kg/km , 696 kg/km , 812 kg/km , 870 kg/km

For fixed installation indoors, outdoors, in the ground, in water and in conrete.

p/nr. Part name Availability Packaging EUR netto pre-metal per 1.000
090435 NA2X2Y-O 01X120 RM 0,6/1 kV SW on request
Stock choose
-
090436 NA2X2Y-O 01X150 RM 0,6/1 kV SW on request
Stock choose
-
090437 NA2X2Y-O 01X185 RM 0,6/1 kV SW on request
Stock choose
-
090442 NA2X2Y-O 01X240 RM 0,6/1 kV SW on request
Stock choose
-
090139 NA2X2Y-O 01X300 RM 0,6/1 kV SW on request
Stock choose
-
090140 NA2X2Y-O 01X500 RM 0,6/1 kV SW on request
Stock choose
-
090141 NA2X2Y-O 01X800 RM 0,6/1 kV SW on request
Stock choose
-
090252 NA2X2Y-J 04X16 RE 0,6/1 kV SW on request
Stock choose
-
090253 NA2X2Y-J 04X25 RE 0,6/1 kV SW on request
Stock choose
-
090254 NA2X2Y-J 04X35 RE 0,6/1 kV SW Stock
Stock choose
-
090255 NA2X2Y-J 04X50 SE 0,6/1 kV SW Stock
Stock choose
-
090256 NA2X2Y-J 04X70 SE 0,6/1 kV SW Stock
Stock choose
-
090257 NA2X2Y-J 04X95 SE 0,6/1 kV SW Stock
Stock choose
-
090258 NA2X2Y-J 04X120 SE 0,6/1 kV SW Stock
Stock choose
-
090259 NA2X2Y-J 04X150 SE 0,6/1 kV SW Stock
Stock choose
-
090260 NA2X2Y-J 04X185 SE 0,6/1 kV SW Stock
Stock choose
-
090121 NA2X2Y-J 04X240 SE 0,6/1 kV SW Stock
Stock choose
-
090122 NA2X2Y-J 04X240 SM 0,6/1 kV SW on request
Stock choose
-

All images shown here are for illustrations and product reference purposes only.

The offered products of this online shop are aimed at entrepreneurs according to §14 BGB, traders, freelancer and public organisations. There is no sale for consumers.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-289
Fax +49 681 97 11-289