flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable suitable for direct burial cable with rodent protection (optical fibre) min. installation temperature 0 °C installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
014556CU/XLPE/PVC/BKA/PVC 7G1.5RM 0.6/1 KV (BS 5467)
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
014557CU/XLPE/PVC/BKA/PVC 12G1.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014558CU/XLPE/PVC/BKA/PVC 19G1.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014559CU/XLPE/PVC/BKA/PVC 7G2.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
015796CU/XLPE/PVC/SWA/PVC 19G2.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013178CU/XLPE/PVC/BKA/PVC 3G1.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013267CU/XLPE/PVC/BKA/PVC 5G1.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014224CU/XLPE/PVC/BKA/PVC 27G1.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012854CU/XLPE/PVC/BKA/PVC 3G2.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012610CU/XLPE/PVC/BKA/PVC 4G2.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013182CU/XLPE/PVC/BKA/PVC 5G2.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014193CU/XLPE/PVC/SWA/PVC 12G2.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013179CU/XLPE/PVC/BKA/PVC 3G4 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013180CU/XLPE/PVC/BKA/PVC 3G6 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013606CU/XLPE/PVC/BKA/PVC 3G10 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014092CU/XLPE/PVC/BKA/PVC 3G16 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013544CU/XLPE/PVC/BKA/PVC 3G25 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013269CU/XLPE/PVC/BKA/PVC 4G1.5RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012855CU/XLPE/PVC/BKA/PVC 4G10 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013181CU/XLPE/PVC/BKA/PVC 4G35 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012611CU/XLPE/PVC/BKA/PVC 4G4 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013183CU/XLPE/PVC/BKA/PVC 5G4 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012929CU/XLPE/PVC/BKA/PVC 4G6 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013184CU/XLPE/PVC/BKA/PVC 5G6 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013185CU/XLPE/PVC/BKA/PVC 5G10 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012612CU/XLPE/PVC/BKA/PVC 4G16 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013186CU/XLPE/PVC/BKA/PVC 5G16 RM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012640CU/XLPE/PVC/BKA/PVC 4G25 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013187CU/XLPE/PVC/BKA/PVC 5G25 SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013517CU/XLPE/PVC/BKA/PVC 5G35 SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012932CU/XLPE/PVC/BKA/PVC 4G50 SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013964CU/XLPE/PVC/BKA/PVC 5G50 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012933CU/XLPE/PVC/BKA/PVC 4G70 SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
015121CU/XLPE/PVC/BKA/PVC 5G70 GY 0.6/1 KV (BS 5467)
on request
AufmachungPreis
015122CU/XLPE/PVC/BKA/PVC 5G70 0.6/1 KV (BS 5467)
on request
AufmachungPreis
012641CU/XLPE/PVC/BKA/PVC 4G95 SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013518CU/XLPE/PVC/BKA/PVC 5G95 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014530CU/XLPE/PVC/BKA/PVC 5G120 0.6/1 KV (BS 5467)
on request
AufmachungPreis
013308CU/XLPE/PVC/BKA/PVC 4G120SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014014CU/XLPE/PVC/BKA/PVC 4G150SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
014036CU/XLPE/PVC/BKA/PVC 4G185SM 0.6/1 KV (BS 5467)
on request
AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Standard BS 5467
Conductor material copper, bare
Conductor construction Class 2 = stranded
Insulation XLPE
Armour round steel wire, galvanized
Sheathing material PVC
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -30 - +70 °C
Permitted outer cable temperature, moved, °C 0 - 70 °C
Bending radius, fixed installation 8 x Ø
metal base Cu 0 EUR/100 kg
Unit of measurement metre

Distribution cable for industry constructions and switching boxes. For fixed installation inside of buildings, direct burial in earth, in water as well as in concrete and for heavy duty mechanical load.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator