CU/AL
0 0

Power cable NYCWY

Power cable NYCWY
  • Item list

  • Technical data

  • Application

  • Technical documents

Customs Tariff Number (code number) 85446010000000000
CPR-performance Eca
Standard VDE 0276-603
Conductor material copper, bare
Conductor construction class 1, from 25 sqmm class 2
Insulation PVC DIV 4
Concentric conductor Cu
Sheathing material PVC DMV5
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
For outdoor use yes
Maximum permitted conductor temperature, °C 70 °C
Permitted outer cable temperature, fixed, °C 70 °C
Permitted outer cable temperature, in motion/during installation, °C -5 - +70 °C
Nominal voltage Uo 600 V
Nominal voltage U 1000 V
Core identification colours acc. to VDE 0293 (HD308)
Core identification colours acc. to VDE 0293 (HD308)
Colour of outer sheath black

The NYCWY cable is a low voltage cable. It belongs to the group of underground cables and is suitable for installation indoors, underground, in water and in concrete.

p/nr. Part name Availability Packaging EN: EUR netto pre-metal per 1.000
080234 NYCWY 01X95 RM/50 BK on request
Stock choose
-
080235 NYCWY 01X240 RM/120 BK on request
Stock choose
-
080001 NYCWY 02X10/10 BK Stock
Stock choose
-
080002 NYCWY 02X16/16 BK Stock
Stock choose
-
080336 NYCWY 02X16 RM/16 BK on request
Stock choose
-
080263 NYCWY 02X25 RM/16 BK on request
Stock choose
-
080233 NYCWY 02X25 RM/25 BK on request
Stock choose
-
080236 NYCWY 02X50 RM/25 BK Stock
Stock choose
-
080003 NYCWY 03X10/10 BK Stock
Stock choose
-
080008 NYCWY 03X16/16 BK Stock
Stock choose
-
080010 NYCWY 03X25/16 BK Stock
Stock choose
-
080012 NYCWY 03X35/16 BK Stock
Stock choose
-
080014 NYCWY 03X50/25 BK Stock
Stock choose
-
080016 NYCWY 03X70/35 BK Stock
Stock choose
-
080018 NYCWY 03X95/50 BK Stock
Stock choose
-
080005 NYCWY 03X120/70 BK Stock
Stock choose
-
080007 NYCWY 03X150/70 BK Stock
Stock choose
-
080009 NYCWY 03X185/95 BK Stock
Stock choose
-
080061 NYCWY 03X240/120 BK Stock
Stock choose
-
080011 NYCWY 03X25/25 BK Stock
Stock choose
-
080013 NYCWY 03X35/35 BK Stock
Stock choose
-
080015 NYCWY 03X50/50 BK Stock
Stock choose
-
080017 NYCWY 03X70/70 BK Stock
Stock choose
-
080019 NYCWY 03X95/95 BK Stock
Stock choose
-
080004 NYCWY 03X120/120 BK Stock
Stock choose
-
080006 NYCWY 03X150/150 BK Stock
Stock choose
-
080259 NYCWY 03X300 SM/150 BK on request
Stock choose
-
080020 NYCWY 04X10/10 BK Stock
Stock choose
-
080023 NYCWY 04X16/16 BK Stock
Stock choose
-
080099 NYCWY 04X16 RM/16 BK on request
Stock choose
-
080025 NYCWY 04X25/16 BK Stock
Stock choose
-
080026 NYCWY 04X35/16 BK Stock
Stock choose
-
080027 NYCWY 04X50/25 BK Stock
Stock choose
-
080028 NYCWY 04X70/35 BK Stock
Stock choose
-
080029 NYCWY 04X95/50 BK Stock
Stock choose
-
080021 NYCWY 04X120/70 BK Stock
Stock choose
-
080022 NYCWY 04X150/70 BK Stock
Stock choose
-
080024 NYCWY 04X185/95 BK Stock
Stock choose
-
080062 NYCWY 04X240/120 BK Stock
Stock choose
-
080254 NYCWY 04X300 SM/150 BK Stock
Stock choose
-

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metall regarding the daily market price.

NYCWY cable—meaning

The abbreviation NYCWY is the type code for a power cable. The individual parts tell you about the material and design of each cable component. The primary feature is the first letter “N”, specifying that it is a standard line according to the national VDE standard. The other letters provide information about the cable structure. From inside to outside, they specify the core insulation and other attributes. The added numbers also show the strand count and their cross sections. For more information such as nominal voltage or test voltage, please see our data sheet for NYCWY.

Example for the NYCWY designation: NYCWY 4x120/70

N: standard cable according to VDE
Y: core insulation made from PVC
CW: shielded, concentric conductor, applied in waveform
Y: outer sheath made from PVC
4: strand count
X: times
120/70: conductor cross section in mm², in this case, 120mm2 with a PE of 70mm²

NYCWY structure

The power cable’s type code already provides information about the essential aspects of the NYCWY structure. The structure specification starts with the inner part of the cable and goes from the conductor and/or core to the outer sheath, using the designation NYCWY. Accordingly, the first Y stands for the core insulation material and the second letter for the outer sheath material. In both cases, this material is polyvinyl chloride (PVC), enabling the diverse ranges of application of the power cable NYCWY and contributing to its weather resistance.

Use and ranges of application of the NYCWY cable

NYCWY is a real multi-tasker. The ranges of application of the NYCWY cable include installation in cable ducts and switchgear. Its use is not limited to indoor applications—it can be installed as an underground cable directly in the soil and applied as a distribution cable in local networks. Thanks to the PVC outer sheath, there are no restrictions on its installation in water or concrete.

NYCWY 4x50/25, NYCWY 4x185/95, NYCWY 4x25/16 and more: Discover Faber’s product variety.

As varied as the use of the NYCWY cable, as extensive is the selection you will find at Faber. Apart from a steady goods availability, we will also be happy to advise you on all the cables perfectly fitting your ranges of application. You need a specific test voltage? You are looking for special cables with aluminium or copper conductors? Or maybe your application has a certain relevant operating temperature? Our experts will help you choose NYCWY and other cables tailored to your requirements. Whether solid core or multi-strand—NYCY, NWCY and many more: Faber provides you with a choice of a multitude of cables in a wide range of cross-sections and lengths such as NYCWY 4x70sm/35 and NYCWY 5x16.

The offered products of this online shop are aimed at entrepreneurs according to §14 BGB, traders, freelancer and public organisations. There is no sale for consumers.

Who we are

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact

 

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Deutschland

Phone +49 681 97 11-289
Fax +49 681 97 11-289