NYY-J/-O NYY cable

Item list
Technical data
Application
Technical documents
Customs Tariff Number (code number) | 85446010000000000 |
CPR-classification according to EN 50575 | Eca |
Standard | VDE 0276-603 |
Conductor material | copper, bare |
Conductor construction | class 1, from 25 sqmm class 2 |
Insulation | PVC DIV 4 |
Sheathing material | PVC DMV5 |
Colour of outer sheath | black |
Flame-retardant | VDE 0482-332-1-2/IEC 60332-1-2 |
UV-resistant | yes |
For outdoor use | yes |
Max. temperature at conductor, °C | 70 °C |
Permitted outer cable temperature, fixed, °C | 70 °C |
Permitted outer cable temperature, moved, °C | -5 - +70 °C |
Cross-section of concentric conductor | - |
Colour of outer sheath | black |
metal base Cu | 0 EUR/100 kg |
Unit of measurement | metre |
In Faber's range of cables, you can find NYY-J cables and NYY-O cables by the metre. The NYY power cables are used as underground cables for power distribution in a wide range of applications. Depending on the application, underground cables are available in different models with one to five cores and a conductor cross-section of 1.5 mm² to 800 mm².
All images shown here are for illustrations and product reference purposes only.
Freight cost extra. Prices plus metal regarding the daily market price.
NYY cables are further specified by type abbreviations consisting of letters and numbers. The NYY cable specification provides information on the design and intended use of the cables and wires. "N" indicates that it is a standard cable according to th
N: standard cable according to the standard VDE 0276-603 YY: PVC core isolation and PVC cable bundle isolation J: with protective conductor O: without protective conductor 5: number of cores x: times 1.5: conductor cross-section in square millimetres
Example for a specification: power cable NYY-J/-O 5x1.5
N: standard cable according to the standard VDE 0276-603
YY: PVC core isolation and PVC cable bundle isolation
J: with protective conductor
O: without protective conductor 5: number of cores x: times 1.5: conductor cross-section in square millimetres
NYY cables specially made for underground installation
NYY cables with a bare copper conductor can be installed indoors, outdoors, underground, in water and in concrete. Thanks to their good isolation, high resistance to environmental influences and long service life, it is possible to install NYY cables directly underground, however, NYY underground cables can also be installed in cable ducts.
Areas of application of NYY cables
Flame-retardant and UV-resistant NYY cables can be used as indoor and outdoor cables and can be used as power distribution cables in power plants, industrial plants, switchboards and local networks. NYY-J and NYY-O cables are also used in building installations. NYY cables with a conductor cross-section of 1.5 mm² are suitable for the connection of individual sockets, whereas NYY wires with a cross-section of 2.5 mm² are designed for supplying several sockets and electrical connections. The most common NYY cables and wires are the NYY 5x1.5, NYY 5x2.5, NYY 5x6, NYY 3x1.5, NYY 3x2.5, and others.
NYY-J and NYY-O cables from the cable expert Faber
You can rely on our many years of experience and expertise in the field of underground cables with cable type NYY. We are happy to advise you and help you find the right NYY cable for your individual application.