max. permitted temperature at conductor 90 °C cable suitable for direct burial min. installation temperature -20 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with VDE-certification cable with EAC-approval
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
011352N2XS2Y 1X35/16 6/10 kV BK
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
011353N2XS2Y 1X50/16 6/10 kV BK
on request
AufmachungPreis
011354N2XS2Y 1X70/16 6/10 kV BK
on request
AufmachungPreis
013132N2XS2Y 1X70/50 6/10 kV BK
on request
AufmachungPreis
011355N2XS2Y 1X95/16 6/10 kV BK
in stock
AufmachungPreis
011356N2XS2Y 1X120/16 6/10 kV BK
in stock
AufmachungPreis
011357N2XS2Y 1X150/16 6/10 kV BK
on request
AufmachungPreis
011358N2XS2Y 1X150/25 6/10 kV BK
in stock
AufmachungPreis
013133N2XS2Y 1X150/50 6/10 kV BK
on request
AufmachungPreis
011359N2XS2Y 1X185/16 6/10 kV BK
on request
AufmachungPreis
011360N2XS2Y 1X185/25 6/10 kV BK
in stock
AufmachungPreis
011361N2XS2Y 1X240/16 6/10 kV BK
on request
AufmachungPreis
011362N2XS2Y 1X240/25 6/10 kV BK
on request
AufmachungPreis
013134N2XS2Y 1X240/50 6/10 kV BK
on request
AufmachungPreis
011363N2XS2Y 1X300/25 6/10 kV BK
on request
AufmachungPreis
011364N2XS2Y 1X400/35 6/10 kV BK
on request
AufmachungPreis
011365N2XS2Y 1X500/35 6/10 kV BK
on request
AufmachungPreis
011366N2XS2Y 1X35/16 12/20 kV BK
on request
AufmachungPreis
011367N2XS2Y 1X50/16 12/20 kV BK
on request
AufmachungPreis
011368N2XS2Y 1X70/16 12/20 kV BK
in stock
AufmachungPreis
011369N2XS2Y 1X95/16 12/20 kV BK
in stock
AufmachungPreis
011370N2XS2Y 1X120/16 12/20 kV BK
on request
AufmachungPreis
011371N2XS2Y 1X150/16 12/20 kV BK
on request
AufmachungPreis
011372N2XS2Y 1X150/25 12/20 kV BK
in stock
AufmachungPreis
011373N2XS2Y 1X185/16 12/20 kV BK
on request
AufmachungPreis
011374N2XS2Y 1X185/25 12/20 kV BK
in stock
AufmachungPreis
011375N2XS2Y 1X240/16 12/20 kV BK
on request
AufmachungPreis
011376N2XS2Y 1X240/25 12/20 kV BK
in stock
AufmachungPreis
011377N2XS2Y 1X300/25 12/20 kV BK
in stock
AufmachungPreis
013215N2XS2Y 1X300/35 12/20 kV BK
on request
AufmachungPreis
011378N2XS2Y 1X400/35 12/20 kV BK
in stock
AufmachungPreis
011379N2XS2Y 1X500/35 12/20 kV BK
on request
AufmachungPreis
013154N2XS2Y 1X630/35 12/20 kV BK
on request
AufmachungPreis
011380N2XS2Y 1X50/16 18/30 kV BK
on request
AufmachungPreis
011383N2XS2Y 1X70/16 18/30 kV BK
on request
AufmachungPreis
011384N2XS2Y 1X95/16 18/30 kV BK
on request
AufmachungPreis
011385N2XS2Y 1X120/16 18/30 kV BK
on request
AufmachungPreis
011386N2XS2Y 1X150/25 18/30 kV BK
on request
AufmachungPreis
011995N2XS2Y 1X150/50 18/30 kV BK
on request
AufmachungPreis
011387N2XS2Y 1X185/25 18/30 kV BK
on request
AufmachungPreis
011388N2XS2Y 1X240/25 18/30 kV BK
on request
AufmachungPreis
015603N2XS2Y 1X240/35 18/30KV BK
on request
AufmachungPreis
011777N2XS2Y 1X240/70 18/30 kV BK
on request
AufmachungPreis
011389N2XS2Y 1X300/25 18/30 kV BK
on request
AufmachungPreis
013686N2XS2Y 1X300/35 18/30 kV BK
on request
AufmachungPreis
013135N2XS2Y 1X300 RM/50 18/30 kV BK
on request
AufmachungPreis
011390N2XS2Y 1X400/35 18/30 kV BK
on request
AufmachungPreis
011391N2XS2Y 1X500/35 18/30 kV BK
on request
AufmachungPreis
013037N2XS2Y 1X630/35 18/30 kV BK
on request
AufmachungPreis
Standard VDE 0276-620
Conductor material copper, bare
Conductor construction Class 2 = stranded
Insulation XLPE DIX8
Electrical field control inner and outer semiconducting layer (triple extrusion)
Screen Copper wires + counter helix
Sheathing material polyethylene DMP2
Colour of outer sheath black
Flame-retardant none
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C 70 °C
Permitted outer cable temperature, moved, °C -20 - +70 °C
Bending radius, fixed installation 15 x Ø
Conductor shape round
Number of cores 1
Wall thickness of sheath 2.1 mm
Colour of outer sheath black
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zero-halogen, yet not flame-retardant as defined under DIN VDE 0482-332-1. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator