installation in free air without UV-protection (cable UV-resistant) max. permitted temperature at conductor 90 °C min. installation temperature -20 °C cable for use in water cable suitable for direct burial cable with EAC-approval cable with VDE-certification
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
014211NA2XS(F)2Y 3X1X120/16 18/30 kV BK
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
014212NA2XS(F)2Y 3X1X150/25 18/30 kV BK
on request
AufmachungPreis
013243NA2XS(F)2Y 3X1X185/25 18/30 kV BK
on request
AufmachungPreis
014213NA2XS(F)2Y 3X1X240/25 18/30 kV BK
on request
AufmachungPreis
013962NA2XS(F)2Y 3X1X300/25 18/30 kV BK
on request
AufmachungPreis
013944NA2XS(F)2Y 3X1X50/25 12/20 kV BK
on request
AufmachungPreis
012683NA2XS(F)2Y 3X1X95/16 12/20 kV BK
on request
AufmachungPreis
012809NA2XS(F)2Y 3X1X120/16 12/20 kV BK
on request
AufmachungPreis
011977NA2XS(F)2Y 3X1X150/25 12/20 kV BK
in stock
AufmachungPreis
015751NA2XS(F)2Y 3X1X150/50 12/20KV SW
on request
AufmachungPreis
012684NA2XS(F)2Y 3X1X185/25 12/20 kV BK
in stock
AufmachungPreis
012685NA2XS(F)2Y 3X1X240/25 12/20 kV BK
in stock
AufmachungPreis
013270NA2XS(F)2Y 3X1X240/35 12/20 kV BK
on request
AufmachungPreis
012686NA2XS(F)2Y 3X1X300/25 12/20 kV BK
on request
AufmachungPreis
012687NA2XS(F)2Y 3X1X400/35 12/20 kV BK
on request
AufmachungPreis
012688NA2XS(F)2Y 3X1X500/35 12/20 kV BK
on request
AufmachungPreis
012689NA2XS(F)2Y 3X1X70/16 6/10 kV BK
on request
AufmachungPreis
013923NA2XS(F)2Y 3X1X95/16 6/10 kV BK
on request
AufmachungPreis
012050NA2XS(F)2Y 3X1X150/25 6/10 kV BK
in stock
AufmachungPreis
012222NA2XS(F)2Y 3X1X185/25 6/10 kV BK
in stock
AufmachungPreis
011787NA2XS(F)2Y 3X1X240/25 6/10 kV BK
in stock
AufmachungPreis
015289NA2XS(F)2Y 3X1X300/25 6/10 kV BK
on request
AufmachungPreis
014773NA2XS(F)2Y 3X1X400/35 6/10 kV BK
on request
AufmachungPreis
015547NA2XS(F)2Y 3X1X500/35 6/10 kV BK
on request
AufmachungPreis
Customs Tariff Number (code number) 85446090000000000
Standard VDE 0276-620
Conductor material aluminium
Conductor construction Class 2 = stranded
Insulation XLPE DIX8
Electrical field control inner and outer semiconducting layer (triple extrusion)
Screen Copper wires + counter helix
Sheathing material polyethylene DMP2
Longitudinally watertight yes
Colour of outer sheath black
Flame-retardant none
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C 70 °C
Permitted outer cable temperature, moved, °C -20 - +70 °C
Bending radius, fixed installation 15 x Ø
Conductor shape (Faber) RMv
Number of cores 3
Wall thickness of sheath 2.1 mm
Colour of outer sheath black
metal base Al (ger) 0 EUR/100 kg
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact