max. permitted temperature at conductor 90 °C cable suitable for direct burial min. installation temperature -20 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with VDE-certification cable with EAC-approval
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
011463NA2XS(F)2Y 1X50/16 06/10 kV BK
in stock
Aufmachung

Log in to see prices

New here? Register now
Preis
011464NA2XS(F)2Y 1X70/16 06/10 kV BK
on request
AufmachungPreis
011465NA2XS(F)2Y 1X95/16 06/10 kV BK
in stock
AufmachungPreis
011466NA2XS(F)2Y 1X120/16 06/10 kV BK
in stock
AufmachungPreis
011467NA2XS(F)2Y 1X150/25 06/10 kV BK
in stock
AufmachungPreis
011468NA2XS(F)2Y 1X185/25 06/10 kV BK
in stock
AufmachungPreis
011469NA2XS(F)2Y 1X240/25 06/10 kV BK
in stock
AufmachungPreis
011470NA2XS(F)2Y 1X300/25 06/10 kV BK
in stock
AufmachungPreis
011471NA2XS(F)2Y 1X400/35 06/10 kV BK
on request
AufmachungPreis
012925NA2XS(F)2Y 1X400/50 06/10 kV BK
on request
AufmachungPreis
011472NA2XS(F)2Y 1X500/35 06/10 kV BK
in stock
AufmachungPreis
012053NA2XS(F)2Y 1X630/35 06/10 kV BK
on request
AufmachungPreis
013230NA2XS(F)2Y 1X800/35 06/10 kV BK
on request
AufmachungPreis
013032NA2XS(F)2Y 1X1000/35 06/10 kV BK
on request
AufmachungPreis
011473NA2XS(F)2Y 1X50/16 12/20 kV BK
in stock
AufmachungPreis
011474NA2XS(F)2Y 1X70/16 12/20 kV BK
in stock
AufmachungPreis
011320NA2XS(F)2Y 1X95/16 12/20 kV BK
in stock
AufmachungPreis
011319NA2XS(F)2Y 1X120/16 12/20 kV BK
in stock
AufmachungPreis
012785NA2XS(F)2Y 1X150/16 12/20 kV BK
on request
AufmachungPreis
011306NA2XS(F)2Y 1X150/25 12/20 kV BK
in stock
AufmachungPreis
013062NA2XS(F)2Y 1X150/50 12/20 kV BK
on request
AufmachungPreis
011307NA2XS(F)2Y 1X185/25 12/20 kV BK
in stock
AufmachungPreis
011308NA2XS(F)2Y 1X240/25 12/20 kV BK
in stock
AufmachungPreis
011475NA2XS(F)2Y 1X300/25 12/20 kV BK
in stock
AufmachungPreis
013063NA2XS(F)2Y 1X300/50 12/20 kV BK
on request
AufmachungPreis
011476NA2XS(F)2Y 1X400/35 12/20 kV BK
in stock
AufmachungPreis
011477NA2XS(F)2Y 1X500/35 12/20 kV BK
in stock
AufmachungPreis
013064NA2XS(F)2Y 1X500/50 12/20 kV BK
on request
AufmachungPreis
011838NA2XS(F)2Y 1X630 RM/35 12/20 kV BK
in stock
AufmachungPreis
013065NA2XS(F)2Y 1X630/50 12/20 kV BK
on request
AufmachungPreis
012258NA2XS(F)2Y 1X800/35 12/20 kV BK
on request
AufmachungPreis
013121NA2XS(F)2Y 1X1000/35 12/20 kV BK
in stock
AufmachungPreis
011534NA2XS(F)2Y 1X50/16 18/30 kV BK
on request
AufmachungPreis
011478NA2XS(F)2Y 1X70/16 18/30 kV BK
on request
AufmachungPreis
011535NA2XS(F)2Y 1X95/16 18/30 kV BK
in stock
AufmachungPreis
013275NA2XS(F)2Y 1X95/35 18/30 kV BK
on request
AufmachungPreis
011536NA2XS(F)2Y 1X120/16 18/30 kV BK
in stock
AufmachungPreis
013276NA2XS(F)2Y 1X120/35 18/30 kV BK
on request
AufmachungPreis
011537NA2XS(F)2Y 1X150/25 18/30 kV BK
in stock
AufmachungPreis
013279NA2XS(F)2Y 1X150/35 18/30 kV BK
on request
AufmachungPreis
011538NA2XS(F)2Y 1X185/25 18/30 kV BK
in stock
AufmachungPreis
013277NA2XS(F)2Y 1X185/35 18/30 kV BK
on request
AufmachungPreis
011539NA2XS(F)2Y 1X240/25 18/30 kV BK
in stock
AufmachungPreis
011540NA2XS(F)2Y 1X300/25 18/30 kV BK
in stock
AufmachungPreis
013280NA2XS(F)2Y 1X300/35 18/30 kV BK
on request
AufmachungPreis
011541NA2XS(F)2Y 1X400/35 18/30 kV BK
on request
AufmachungPreis
011542NA2XS(F)2Y 1X500/35 18/30 kV BK
in stock
AufmachungPreis
013278NA2XS(F)2Y 1X500/50 18/30 kV BK
on request
AufmachungPreis
012223NA2XS(F)2Y 1X630/35 18/30 kV BK
in stock
AufmachungPreis
013067NA2XS(F)2Y 1X800/35 18/30 kV BK
in stock
AufmachungPreis
013568NA2XS(F)2Y 1X1000/35 18/30 kV BK
in stock
AufmachungPreis
015584NA2XS(F)2YV 1X70/16 12/20KV BK WANDVER.3.0
on request
AufmachungPreis
013570NA2XS(F)2Yv 1X150/25 12/20 kV BK
on request
AufmachungPreis
013207NA2XS(F)2Yv 1X240 RM/25 12/20 kV BK
in stock
AufmachungPreis
013895NA2XS(F)2Yv 1X630/35 12/20 kV BK 3 mm reinforced
in stock
AufmachungPreis
Customs Tariff Number (code number) 85446090000000000
Standard VDE 0276-620
Conductor material aluminium
Conductor construction Class 2 = stranded
Insulation XLPE DIX8
Electrical field control inner and outer semiconducting layer (triple extrusion)
Screen Copper wires + counter helix
Sheathing material polyethylene DMP2
Longitudinally watertight yes
Colour of outer sheath black
Flame-retardant none
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C 70 °C
Permitted outer cable temperature, moved, °C -20 - +70 °C
Bending radius, fixed installation 15 x Ø
Conductor shape round
Conductor shape (Faber) RMv
Number of cores 1
Colour of outer sheath black
metal base Al (ger) 0 EUR/100 kg
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration lengthwise following mechanical damage.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator