installation in free air without UV-protection (cable UV-resistant) max. permitted temperature at conductor 90 °C min. installation temperature -20 °C cable for use in water cable suitable for direct burial cable with EAC-approval cable with VDE-certification
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
013784N2XS(FL)2Y 1X35/16 6/10 kV BK
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
014065N2XS(FL)2Y 1X50/16 6/10 kV BK
on request
AufmachungPreis
013521N2XS(FL)2Y 1X70/16 6/10 kV BK
on request
AufmachungPreis
012467N2XS(FL)2Y 1X95/16 6/10 kV BK
on request
AufmachungPreis
012459N2XS(FL)2Y 1X120/16 6/10 kV BK
on request
AufmachungPreis
015257N2XS(FL)2Y 1X150/16 6/10 kV BK
on request
AufmachungPreis
012639N2XS(FL)2Y 1X150/25 6/10 kV BK
on request
AufmachungPreis
012582N2XS(FL)2Y 1X185/25 6/10 kV BK
on request
AufmachungPreis
011825N2XS(FL)2Y 1X240/25 6/10 kV BK
on request
AufmachungPreis
012001N2XS(FL)2Y 1X300/25 6/10 kV BK
on request
AufmachungPreis
014137N2XS(FL)2Y 1X400/35 6/10 kV BK
on request
AufmachungPreis
012613N2XS(FL)2Y 1X500/35 6/10 kV BK
on request
AufmachungPreis
012654N2XS(FL)2Y 1X630/35 6/10 kV BK
on request
AufmachungPreis
013641N2XS(FL)2Y 1X35/16 12/20 kV BK
on request
AufmachungPreis
013117N2XS(FL)2Y 1X50/16 12/20 kV BK
on request
AufmachungPreis
013118N2XS(FL)2Y 1X70/16 12/20 kV BK
on request
AufmachungPreis
011786N2XS(FL)2Y 1X95/16 12/20 kV BK
on request
AufmachungPreis
013119N2XS(FL)2Y 1X120/16 12/20 kV BK
on request
AufmachungPreis
013033N2XS(FL)2Y 1X150/25 12/20 kV BK
on request
AufmachungPreis
014210N2XS(FL)2Y 1X185/25 12/20 kV BK
on request
AufmachungPreis
013030N2XS(FL)2Y 1X240/25 12/20 kV BK
on request
AufmachungPreis
013663N2XS(FL)2Y 1X95 RM/16 18/30 kV BK
on request
AufmachungPreis
013640N2XS(FL)2Y 1X150/25 18/30 kV BK
on request
AufmachungPreis
013664N2XS(FL)2Y 1X240 RM/25 18/30 kV BK
on request
AufmachungPreis
012779N2XS(FL)2Y 1X300/25 18/30 kV BK
on request
AufmachungPreis
013227N2XS(FL)2Y 1X400/35 18/30 kV BK
on request
AufmachungPreis
015231N2XS(FL)2Y 1X500/35 18/30 kV BK
in stock
AufmachungPreis
011750N2XS(FL)2Y 1X300/25 12/20 kV BK
in stock
AufmachungPreis
013561N2XS(FL)2Y 1X400/35 12/20 kV BK
on request
AufmachungPreis
012228N2XS(FL)2Y 1X500/35 12/20 kV BK
on request
AufmachungPreis
013974N2XS(FL)2Y 1X630/35 12/20 kV BK
on request
AufmachungPreis
015645N2XS(FL)2Y 1X1000/35 12/20KV BK
in stock
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard VDE 0276-620
Conductor material copper, bare
Conductor construction Class 2 = stranded
Insulation XLPE DIX8
Electrical field control inner and outer semiconducting layer (triple extrusion)
Screen Copper wires + counter helix
Sheathing material polyethylene DMP2
bonded sheath yes
Transversely watertight yes
Longitudinally watertight yes
Colour of outer sheath black
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C 70 °C
Permitted outer cable temperature, moved, °C -20 - +70 °C
Bending radius, fixed installation 15 x Ø
Number of cores 1
Wall thickness of sheath 2.1 mm
Colour of outer sheath black
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation. This cable is also suitable for unfavourable operating conditions, specifically where there is a need to avoid water penetration both crosswise and lengthwise following mechanical damage.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact