N2XSY

N2XSY
flame retardant acc. IEC 60332-1-2 cable suitable for direct burial max. permitted temperature at conductor 90 °C min. installation temperature -5 °C installation in free air only with UV-protection (cable not UV-resistant) cable for use in water cable with VDE-certification

flame retardant acc. IEC 60332-1-2flame retardant acc. IEC 60332-1-2

cable suitable for direct burialcable suitable for direct burial

max. permitted temperature at conductor 90 °Cmax. permitted temperature at conductor 90 °C

min. installation temperature -5 °Cmin. installation temperature -5 °C

installation in free air only with UV-protection (cable not UV-resistant)installation in free air only with UV-protection (cable not UV-resistant)

cable for use in watercable for use in water

cable with VDE-certificationcable with VDE-certification

  • Item list
  • Technical data
  • Application
  • Technical documents
Standard VDE 0276-620
Conductor material copper, bare
Conductor class class 2 = stranded
Insulation XLPE DIX8
Sheathing material PVC DMV6
Colour outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
For outdoor use yes
Maximum permitted conductor temperature 90 °C
Permitted outer cable temperature, fixed 70 °C
Permitted outer cable temperature, in motion/during installation -5 - +70 °C
Bending radius, fixed installation 15 x DA
Nominal voltage Uo 12000 V , 18000 V , 6000 V
Nominal voltage U 10000 V , 20000 V , 30000 V
Maximum permitted operating voltage in three-phase systems 12 kV , 24 kV , 36 kV
Test voltage 24 kV , 42 kV , 63 kV
Conductor shape round
Conductor shape (Faber) RM , RMv
Number of cores 1
Conductor diameter 10.2 mm , 12 mm , 12.0 mm , 13.5 mm , 15 mm , 15.0 mm , 16.8 mm , 19.2 mm , 21.6 mm , 24.6 mm , 27.6 mm , 32.5 mm , 37.6 mm , 7.5 mm , 8.6 mm
Nominal cross section 120 mm² , 150 mm² , 185 mm² , 240 mm² , 300 mm² , 35 mm² , 400 mm² , 50 mm² , 500 mm² , 630 mm² , 70 mm² , 800 mm² , 95 mm²
Conductor resistance 0.0221 Ohm/km , 0.0283 Ohm/km , 0.0366 Ohm/km , 0.047 Ohm/km , 0.0601 Ohm/km , 0.0754 Ohm/km , 0.0991 Ohm/km , 0.124 Ohm/km , 0.153 Ohm/km , 0.193 Ohm/km , 0.268 Ohm/km , 0.387 Ohm/km , 0.524 Ohm/km
Insulation wall thickness 3.4 mm , 5.5 mm , 8 mm
Ampacity in air (30 °C) 1075 A , 1090 A , 1205 A , 197 A , 200 A , 202 A , 236 A , 239 A , 241 A , 294 A , 297 A , 299 A , 358 A , 361 A , 363 A , 413 A , 416 A , 418 A , 468 A , 470 A , 472 A , 535 A , 538 A , 539 A , 631 A , 634 A , 635 A , 722 A , 724 A , 725 A , 827 A , 829 A , 831 A , 949 A , 953 A
Ampacity in ground (20 °C) 187 A , 189 A , 191 A , 220 A , 222 A , 225 A , 268 A , 271 A , 274 A , 320 A , 323 A , 327 A , 363 A , 367 A , 371 A , 405 A , 409 A , 414 A , 456 A , 461 A , 466 A , 526 A , 532 A , 539 A , 591 A , 599 A , 606 A , 662 A , 671 A , 680 A , 744 A , 754 A , 765 A , 820 A , 890 A
Short-circuit current (1 s) 10 kA , 114.4 kA , 13.6 kA , 17.2 kA , 21.4 kA , 26.5 kA , 34.3 kA , 42.9 kA , 5 kA , 57.2 kA , 7.15 kA , 71.5 kA , 90.1 kA
Wall thickness of sheath 2.5 mm
Bending radius, fixed installation 360 mm , 375 mm , 405 mm , 420 mm , 435 mm , 450 mm , 465 mm , 480 mm , 495 mm , 510 mm , 525 mm , 540 mm , 555 mm , 585 mm , 600 mm , 615 mm , 630 mm , 660 mm , 675 mm , 705 mm , 735 mm , 750 mm , 795 mm , 900 mm
Conductor class class 2 = stranded
Outer diameter approx. 24 mm , 25 mm , 27 mm , 28 mm , 29 mm , 30 mm , 31 mm , 32 mm , 33 mm , 34 mm , 35 mm , 36 mm , 37 mm , 39 mm , 40 mm , 41 mm , 42 mm , 44 mm , 45 mm , 47 mm , 49 mm , 50 mm , 53 mm , 60 mm , 62 mm
Colour of outer sheath red
Tensile strength (during installation) 12000 N , 15000 N , 1750 N , 20000 N , 2500 N , 25000 N , 31500 N , 3500 N , 40000 N , 4750 N , 6000 N , 7500 N , 9250 N
Copper weight (GER) 1094 kg/km , 1334 kg/km , 1622 kg/km , 1723 kg/km , 1958 kg/km , 2059 kg/km , 2486 kg/km , 2587 kg/km , 2864 kg/km , 3163 kg/km , 4234 kg/km , 518 kg/km , 5194 kg/km , 6442 kg/km , 662 kg/km , 8074 kg/km , 8094 kg/km , 8240 kg/km , 854 kg/km

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE 0276-603 cables must be protected from sunlight.

p/nr. Part name Availability Packaging EUR netto pre-metal per 1.000
011292 N2XSY 01X35/16 6/10 kV RT Stock
Stock choose
-
011288 N2XSY 01X50/16 6/10 kV RT Stock
Stock choose
-
011289 N2XSY 01X70/16 6/10 kV RT Stock
Stock choose
-
011326 N2XSY 01X95/16 6/10 kV RT Stock
Stock choose
-
011290 N2XSY 01X120/16 6/10 kV RT Stock
Stock choose
-
011327 N2XSY 01X150/16 6/10 kV RT on request
Stock choose
-
011291 N2XSY 01X150/25 6/10 kV RT Stock
Stock choose
-
011328 N2XSY 01X185/16 6/10 kV RT on request
Stock choose
-
011329 N2XSY 01X185/25 6/10 kV RT Stock
Stock choose
-
011330 N2XSY 01X240/16 6/10 kV RT on request
Stock choose
-
011294 N2XSY 01X240/25 6/10 kV RT Stock
Stock choose
-
011331 N2XSY 01X300/25 6/10 kV RT Stock
Stock choose
-
011332 N2XSY 01X400/35 6/10 kV RT on request
Stock choose
-
011333 N2XSY 01X500/35 6/10 kV RT Stock
Stock choose
-
011295 N2XSY 01X35/16 12/20 kV RT Stock
Stock choose
-
011296 N2XSY 01X50/16 12/20 kV RT Stock
Stock choose
-
011297 N2XSY 01X70/16 12/20 kV RT Stock
Stock choose
-
011298 N2XSY 01X95/16 12/20 kV RT Stock
Stock choose
-
011318 N2XSY 01X120/16 12/20 kV RT Stock
Stock choose
-
011334 N2XSY 01X150/16 12/20 kV RT on request
Stock choose
-
011335 N2XSY 01X150/25 12/20 kV RT Stock
Stock choose
-
011336 N2XSY 01X185/16 12/20 kV RT on request
Stock choose
-
011299 N2XSY 01X185/25 12/20 kV RT Stock
Stock choose
-
011337 N2XSY 01X240/16 12/20 kV RT on request
Stock choose
-
011338 N2XSY 01X240/25 12/20 kV RT Stock
Stock choose
-
012691 N2XSY 01X240/50 12/20 kV RT on request
Stock choose
-
011339 N2XSY 01X300/25 12/20 kV RT Stock
Stock choose
-
011341 N2XSY 01X400/35 12/20 kV RT on request
Stock choose
-
011340 N2XSY 01X500/35 12/20 kV RT Stock
Stock choose
-
012566 N2XSY 01X630/35 12/20 kV RT on request
Stock choose
-
012692 N2XSY 01X800/50 12/20 kV RT on request
Stock choose
-
013657 N2XSY 01X35/16 18/30 kV RT on request
Stock choose
-
011342 N2XSY 01X50/16 18/30 kV RT Stock
Stock choose
-
011343 N2XSY 01X70/16 18/30 kV RT on request
Stock choose
-
011344 N2XSY 01X95/16 18/30 kV RT on request
Stock choose
-
011345 N2XSY 01X120/16 18/30 kV RT Stock
Stock choose
-
011346 N2XSY 01X150/25 18/30 kV RT on request
Stock choose
-
011347 N2XSY 01X185/25 18/30 kV RT on request
Stock choose
-
011348 N2XSY 01X240/25 18/30 kV RT Stock
Stock choose
-
011349 N2XSY 01X300/25 18/30 kV RT on request
Stock choose
-
011350 N2XSY 01X400/35 18/30 kV RT on request
Stock choose
-
011351 N2XSY 01X500/35 18/30 kV RT on request
Stock choose
-
014272 N2XSY 01X800 RM/35 18/30 kV RT on request
Stock choose
-
011529 N2XSY 01X800/35 12/20 kV RT on request
Stock choose
-
011976 N2XSY 01X630/35 6/10 kV RT on request
Stock choose
-

All images shown here are for illustrations and product reference purposes only.

The offered products of this online shop are aimed at entrepreneurs according to §14 BGB, traders, freelancer and public organisations. There is no sale for consumers.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-289
Fax +49 681 97 11-289