2% Rabatt auf Online-Bestellungen
Details
cable suitable for direct burial max. permitted temperature at conductor 90 °C min. installation temperature -20 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with VDE-certification cable with EAC-approval
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
011431NA2XS2Y 1X50/16 06/10 kV BK
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
011432NA2XS2Y 1X70/16 06/10 kV BK
on request
AufmachungPreis
011433NA2XS2Y 1X95/16 06/10 kV BK
on request
AufmachungPreis
011498NA2XS2Y 1X120/16 06/10 kV BK
on request
AufmachungPreis
013074NA2XS2Y 1X120/50 06/10 kV BK
on request
AufmachungPreis
011434NA2XS2Y 1X150/16 06/10 kV BK
on request
AufmachungPreis
011435NA2XS2Y 1X150/25 06/10 kV BK
on request
AufmachungPreis
011436NA2XS2Y 1X185/16 06/10 kV BK
on request
AufmachungPreis
011437NA2XS2Y 1X185/25 06/10 kV BK
in stock
AufmachungPreis
011438NA2XS2Y 1X240/16 06/10 kV BK
on request
AufmachungPreis
011439NA2XS2Y 1X240/25 06/10 kV BK
in stock
AufmachungPreis
011440NA2XS2Y 1X300/25 06/10 kV BK
on request
AufmachungPreis
011441NA2XS2Y 1X400/35 06/10 kV BK
on request
AufmachungPreis
011442NA2XS2Y 1X500/35 06/10 kV BK
on request
AufmachungPreis
013026NA2XS2Y 1X630/35 6/10 kV BK
on request
AufmachungPreis
012811NA2XS2Y 1X35/16 12/20 kV BK
on request
AufmachungPreis
011443NA2XS2Y 1X50/16 12/20 kV BK
on request
AufmachungPreis
011444NA2XS2Y 1X70/16 12/20 kV BK
on request
AufmachungPreis
013027NA2XS2Y 1X70/25 12/20 kV BK
on request
AufmachungPreis
011324NA2XS2Y 1X95/16 12/20 kV BK
in stock
AufmachungPreis
011323NA2XS2Y 1X120/16 12/20 kV BK
in stock
AufmachungPreis
013075NA2XS2Y 1X120/50 12/20 kV BK
on request
AufmachungPreis
011445NA2XS2Y 1X150/16 12/20 kV BK
on request
AufmachungPreis
011325NA2XS2Y 1X150/25 12/20 kV BK
in stock
AufmachungPreis
011446NA2XS2Y 1X185/16 12/20 kV BK
on request
AufmachungPreis
011321NA2XS2Y 1X185/25 12/20 kV BK
in stock
AufmachungPreis
011449NA2XS2Y 1X240/16 12/20 kV BK
on request
AufmachungPreis
011448NA2XS2Y 1X240/25 12/20 kV BK
in stock
AufmachungPreis
013076NA2XS2Y 1X240/50 12/20 kV BK
on request
AufmachungPreis
011450NA2XS2Y 1X300/25 12/20 kV BK
on request
AufmachungPreis
011451NA2XS2Y 1X400/35 12/20 kV BK
on request
AufmachungPreis
011452NA2XS2Y 1X500/35 12/20 kV BK
on request
AufmachungPreis
013077NA2XS2Y 1X500/50 12/20 kV BK
on request
AufmachungPreis
012227NA2XS2Y 1X630/35 12/20 kV BK
on request
AufmachungPreis
013152NA2XS2Y 1X800/35 12/20 kV BK
on request
AufmachungPreis
011453NA2XS2Y 1X50/16 18/30 kV BK
on request
AufmachungPreis
011454NA2XS2Y 1X70/16 18/30 kV BK
on request
AufmachungPreis
011455NA2XS2Y 1X95/16 18/30 kV BK
on request
AufmachungPreis
011456NA2XS2Y 1X120/16 18/30 kV BK
in stock
AufmachungPreis
011457NA2XS2Y 1X150/25 18/30 kV BK
on request
AufmachungPreis
011458NA2XS2Y 1X185/25 18/30 kV BK
on request
AufmachungPreis
011459NA2XS2Y 1X240/25 18/30 kV BK
on request
AufmachungPreis
011460NA2XS2Y 1X300/25 18/30 kV BK
on request
AufmachungPreis
011461NA2XS2Y 1X400/35 18/30 kV BK
on request
AufmachungPreis
011462NA2XS2Y 1X500/35 18/30 kV BK
on request
AufmachungPreis
013116NA2XS2Y 1X630/35 18/30 kV BK
on request
AufmachungPreis
Customs Tariff Number (code number) 85446090000000000
Standard VDE 0276-620
Conductor material aluminium
Conductor construction Class 2 = stranded
Insulation XLPE DIX8
Electrical field control inner and outer semiconducting layer (triple extrusion)
Screen Copper wires + counter helix
Sheathing material polyethylene DMP2
Colour of outer sheath black
Flame-retardant none
UV-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C 70 °C
Permitted outer cable temperature, moved, °C -20 - +70 °C
Bending radius, fixed installation 15 x Ø
Number of cores 1
Colour of outer sheath black
metal base Al (ger) 0 EUR/100 kg
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. It should be noted during installation in cable ducts and interior spaces that the PE-sheath is zero-halogen, yet not flame-retardant as defined under DIN VDE 0482-332-1. The high mechanical durability of the PE-sheath permits strong mechanical stress during installation or operation.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator