2% Rabatt auf Online-Bestellungen
Details
flame retardant acc. IEC 60332-3-24 screened cable cable suitable for direct burial cable with rodent protection (optical fibre) not for application in power circuits cable to a large extent oil resistant min. installation temperature -5 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive
1016730400500
drum 500 m
Invalid input!
on request
Price
Price
Price
1016730401000
drum 1000 m
Invalid input!
on request
Price
Price
Price
1016730400000
cut length
Invalid input!
on request
Price
Price
Price

Log in to see prices

New here? Register now
0
Customs Tariff Number (code number) 85444995900000000
Conductor material copper, bare
Conductor construction class 2, 7-wired construction
Insulation XLPE
Stranding unit Triple
Stranding Layers
Core wrapping plastic foil
Material inner sheath PVC
Screen plastic coated Al-foil + copper drain wire, tinned
Armour round or flat steel wires, galvanized
Sheathing material PVC
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
UV-resistant yes
Oil-resistant yes
For outdoor use yes
Permitted outer cable temperature, fixed, °C -30 - +70 °C
Permitted outer cable temperature, moved, °C -5 - +50 °C
Bending radius, fixed installation 10 x Ø
Insulation resistance 5000 MOhmxkm
Specific inductivity 1 mH/km
Core identification black-white-orange with numbers
Number of cores 6
Nominal cross section, sqmm 1.5 mm²
outer diameter approx. 19.10 mm
Copper weight (GER) 101
metal base Cu 100 EUR/100 kg
net weight per 1000 496 kg
Unit of measurement metre
Direct burial yes
Sheathing material PVC
Cable shape round
Halogen-free no
Oil-resistant yes
Colour black
Conductor construction class 2 = stranded
Insulation XLPE

For data communication with transmission rates up to 200 kBit/s in MSR- and EDP systems. Transmission characteristics are guaranteed by high-quality stranding and screening. For fixed installation in dry and damp areas, outdoors and direct burial in earth.The types with blue outer sheath are suitable for intrinsically safe installation -Ex i- in hazardous areas.

All images shown here are for illustrations and product reference purposes only.

Contact
Cable calculator