flame retardant acc. IEC 60332-1-2 screened cable cable to a large extent oil resistant max. permitted temperature at conductor 80 °C min. installation temperature -25 °C cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
0528563X150/70KON+3X(2.5ST KON/2.5UL KON) YE
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
Customs Tariff Number (code number) 85444995900000000
Standard VDE 250-812 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Material inner sheath rubber GM1b
Screen spiral copper wires, tinned
Armour round steel wire, galvanized
Sheathing material rubber (CR) 5GM5
Colour of outer sheath yellow
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
Oil-resistant EN 60811-2-1
Max. temperature at conductor, °C 80 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -25 - +80 °C
Bending radius, fixed installation 4 x Ø
Bending radius, moving application 6 x Ø
Maximum tensile strength at the conductor 15 N/mm²
Nominal cross section, sqmm 150 mm²
outer diameter approx. 72.50 mm
Copper weight (GER) 5390
metal base Cu 150 EUR/100 kg
net weight per 1000 9600 kg
Unit of measurement metre
crane cables / hoist cables yes

As connecting cable for mobile equipment in underground mining on machines with very high mechanical loads. Integrated control and monitoring cores allow insulation faults and damage to the cable to be detected immediately.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator