flame retardant acc. IEC 60332-1-2 screened cable cable to a large extent oil resistant max. permitted temperature at conductor 80 °C min. installation temperature -25 °C cable conform to Low Voltage directive
0528560400500
drum 500 m
Invalid input!
MOQ

MOQ: 1 km

Delivery time: approx. 15 weeks

Price
Price
Price
0528560400000
cut length
Invalid input!
MOQ

MOQ: 1 km

Delivery time: approx. 15 weeks

Price
Price
Price

Log in to see prices

New here? Register now
0
Customs Tariff Number (code number) 85444995900000000
Standard VDE 250-812 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation rubber 3GI3
Material inner sheath rubber GM1b
Screen spiral copper wires, tinned
Armour round steel wire, galvanized
Sheathing material rubber (CR) 5GM5
Colour of outer sheath yellow
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
Oil-resistant EN 60811-2-1
Max. temperature at conductor, °C 80 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -25 - +80 °C
Bending radius, fixed installation 4 x Ø
Bending radius, moving application 6 x Ø
Maximum tensile strength at the conductor 15 N/mm²
Nominal cross section, sqmm 150 mm²
outer diameter approx. 72.50 mm
Copper weight (GER) 5390
metal base Cu 150 EUR/100 kg
net weight per 1000 9600 kg
Unit of measurement metre
crane cables / hoist cables yes
Nominal voltage 0,6/1 kV
Sheathing material rubber
Cable shape round
Halogen-free no
Oil-resistant yes
Colour yellow
Conductor construction class 5 = fine stranded
Insulation rubber

As connecting cable for mobile equipment in underground mining on machines with very high mechanical loads. Integrated control and monitoring cores allow insulation faults and damage to the cable to be detected immediately.

All images shown here are for illustrations and product reference purposes only.

Contact