flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable to a large extent oil resistant min. installation temperature -25 °C installation in free air without UV-protection (cable UV-resistant) cable for use in water cable with EAC-approval
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
053237FABER DREDGING CABLE 3X50+3X25/3E 3.6/6KV RD
on request
Aufmachung

Log in to see prices

New here? Register now
Preis
054550FABER DREDGING CABLE 3X50+3X50/3E 3.6/6KV RD
on request
AufmachungPreis
054551FABER DREDGING CABLE 3X70+3X50/3E 3.6/6KV RD
on request
AufmachungPreis
054552FABER DREDGING CABLE 3X120+3X70/3E 3.6/6KV RD
on request
AufmachungPreis
054553FABER DREDGING CABLE 3X185+3X95/3E 3.6/6KV RD
on request
AufmachungPreis
0528983X35 + 3X25/3E 6/10 kV RD
on request
AufmachungPreis
053238FABER DREDGING CABLE 3X50+3X25/3E 6/10KV RD
on request
AufmachungPreis
054279FABER DREDGING CABLE 3X95+3X50/3E 6/10KV RD
on request
AufmachungPreis
054406FABER DREDGING CABLE 3X240+3X120/3E 6/10KV RD
on request
AufmachungPreis
052719Faber® DREDGING CABLE 3X25+3X25/3E 12/20KV RD
on request
AufmachungPreis
0527043X35 + 3X25/3E 12/20 kV RD
in stock
AufmachungPreis
0527053X50 + 3X25/3E 12/20 kV RD
on request
AufmachungPreis
054443FABER DREDGING CABLE 3X35+3X25/3E 14/25KV RD
on request
AufmachungPreis
0530543X95 + 3X50/3E 12/20 kV RD
on request
AufmachungPreis
Customs Tariff Number (code number) 85446010900000000
Standard DIN VDE 0250-813 (with ref. to)
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation rubber (EPR) 3GI3
Electrical field control inner and outer semiconducting rubber layer
Arrangement of protective conductors tinned copper wire braid over each phase
Material inner sheath rubber GM1b
Sheathing material rubber (CR) 5GM5
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, fixed, °C -40 - +90 °C
Permitted outer cable temperature, moved, °C -25 - +60 °C
Bending radius, fixed installation 6 x Ø
Bending radius, moving application 15 x Ø
Maximum tensile strength at the conductor 15 N/mm²
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

Flexible medium voltage cable for permanent use in water, for example connecting dredgers, floating docks, pumps and open-cast mines.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator