NA2XSY
flame retardant acc. IEC 60332-1-2 cable suitable for direct burial max. permitted temperature at conductor 90 °C min. installation temperature -5 °C installation in free air only with UV-protection (cable not UV-resistant) cable for use in water cable with VDE-certification

flame retardant acc. IEC 60332-1-2flame retardant acc. IEC 60332-1-2

cable suitable for direct burialcable suitable for direct burial

max. permitted temperature at conductor 90 °Cmax. permitted temperature at conductor 90 °C

min. installation temperature -5 °Cmin. installation temperature -5 °C

installation in free air only with UV-protection (cable not UV-resistant)installation in free air only with UV-protection (cable not UV-resistant)

cable for use in watercable for use in water

cable with VDE-certificationcable with VDE-certification

  • Item list
  • Technical data
  • Application
  • Technical documents
Standard VDE 0276-620
Conductor material aluminium
Conductor class class 2 = stranded
Insulation XLPE DIX8
Sheathing material PVC DMV6
Colour outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
For outdoor use yes
Maximum permitted conductor temperature 90 °C
Permitted outer cable temperature, fixed 70 °C
Permitted outer cable temperature, in motion/during installation -5 - +70 °C
Bending radius, fixed installation 15 x DA
Nominal voltage Uo 12000 V , 18000 V , 6000 V
Nominal voltage U 10000 V , 20000 V , 30000 V
Maximum permitted operating voltage in three-phase systems 12 kV , 24 kV , 36 kV
Test voltage 21 kV , 42 kV , 63 kV
Conductor shape (Faber) RMv
Number of cores 1
Conductor diameter 10.2 mm , 12 mm , 12.0 mm , 13.5 mm , 15 mm , 16.8 mm , 19.2 mm , 21.6 mm , 24.6 mm , 27.6 mm , 32.5 mm , 37.6 mm , 8.6 mm
Nominal cross section 1000 mm² , 120 mm² , 150 mm² , 185 mm² , 240 mm² , 300 mm² , 400 mm² , 50 mm² , 500 mm² , 630 mm² , 70 mm² , 800 mm² , 95 mm²
Conductor resistance 0.0367 Ohm/km , 0.0469 Ohm/km , 0.0605 Ohm/km , 0.0778 Ohm/km , 0.100 Ohm/km , 0.125 Ohm/km , 0.164 Ohm/km , 0.206 Ohm/km , 0.253 Ohm/km , 0.320 Ohm/km , 0.443 Ohm/km , 0.641 Ohm/km
Insulation wall thickness 3.4 mm , 5.5 mm , 8 mm
Ampacity in air (30 °C) 1010 A , 183 A , 185 A , 187 A , 228 A , 231 A , 232 A , 278 A , 280 A , 282 A , 321 A , 323 A , 325 A , 364 A , 366 A , 367 A , 418 A , 420 A , 421 A , 494 A , 496 A , 568 A , 569 A , 659 A , 660 A , 764 A , 766 A , 767 A , 890 A
Ampacity in ground (20 °C) 171 A , 172 A , 174 A , 208 A , 210 A , 213 A , 248 A , 251 A , 254 A , 283 A , 285 A , 289 A , 315 A , 319 A , 322 A , 357 A , 361 A , 364 A , 413 A , 417 A , 422 A , 466 A , 471 A , 476 A , 529 A , 535 A , 541 A , 602 A , 609 A , 616 A , 675 A , 745 A
Short-circuit current (1 s) 11.3 kA , 14.1 kA , 17.4 kA , 22.6 kA , 28.2 kA , 37.6 kA , 4.7 kA , 47 kA , 59.2 kA , 6.58 kA , 75.2 kA , 8.93 kA
Wall thickness of sheath 2.5 mm , 2.52 mm
Bending radius, fixed installation 375 mm , 405 mm , 420 mm , 435 mm , 450 mm , 465 mm , 480 mm , 495 mm , 510 mm , 525 mm , 540 mm , 555 mm , 585 mm , 600 mm , 615 mm , 630 mm , 660 mm , 675 mm , 705 mm , 720 mm , 750 mm , 795 mm , 855 mm
Conductor class class 2 = stranded
Outer diameter approx. 25 mm , 27 mm , 28 mm , 29 mm , 30 mm , 31 mm , 32 mm , 33 mm , 34 mm , 34.4 mm , 35 mm , 36 mm , 37 mm , 39 mm , 40 mm , 41 mm , 42 mm , 44 mm , 45 mm , 47 mm , 48 mm , 50 mm , 52 mm , 53 mm , 57 mm , 57.3 mm , 66 mm
Colour of outer sheath red
Tensile strength (during installation) 12000 N , 1500 N , 15000 N , 18900 N , 2100 N , 24000 N , 2850 N , 3600 N , 4500 N , 5550 N , 7200 N , 9000 N
Aluminium weight (GER) 1160 kg/km , 145 kg/km , 1450 kg/km , 1827 kg/km , 203 kg/km , 2320 kg/km , 276 kg/km , 2900 kg/km , 348 kg/km , 435 kg/km , 537 kg/km , 696 kg/km , 870 kg/km
Copper weight (GER) 182 kg/km , 283 kg/km , 394 kg/km , 560 kg/km

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE 0276-603 cables must be protected from sunlight.

p/nr. Part name Availability Packaging EUR netto pre-metal per 1.000
011392 NA2XSY 01X50/16 6/10 kV RT on request
Stock choose
-
011393 NA2XSY 01X70/16 6/10 kV RT on request
Stock choose
-
012614 NA2XSY 01X70/35 6/10 kV RT on request
Stock choose
-
011394 NA2XSY 01X95/16 6/10 kV RT on request
Stock choose
-
011395 NA2XSY 01X120/16 6/10 kV RT on request
Stock choose
-
012615 NA2XSY 01X120/50 6/10 kV RT on request
Stock choose
-
011396 NA2XSY 01X150/16 6/10 kV RT on request
Stock choose
-
011397 NA2XSY 01X150/25 6/10 kV RT on request
Stock choose
-
011398 NA2XSY 01X185/16 6/10 kV RT on request
Stock choose
-
011399 NA2XSY 01X185/25 6/10 kV RT on request
Stock choose
-
011400 NA2XSY 01X240/16 6/10 kV RT on request
Stock choose
-
011401 NA2XSY 01X240/25 6/10 kV RT on request
Stock choose
-
011402 NA2XSY 01X300/25 6/10 kV RT on request
Stock choose
-
011403 NA2XSY 01X400/35 6/10 kV RT on request
Stock choose
-
011404 NA2XSY 01X500/35 6/10 kV RT on request
Stock choose
-
014005 NA2XSY 01X630/35 6/10 kV RT on request
Stock choose
-
011405 NA2XSY 01X50/16 12/20 kV RT on request
Stock choose
-
011406 NA2XSY 01X70/16 12/20 kV RT on request
Stock choose
-
011407 NA2XSY 01X95/16 12/20 kV RT on request
Stock choose
-
011408 NA2XSY 01X120/16 12/20 kV RT on request
Stock choose
-
013031 NA2XSY 1X120/25 12/20 kV RT on request
Stock choose
-
011409 NA2XSY 01X150/16 12/20 kV RT on request
Stock choose
-
011410 NA2XSY 01X150/25 12/20 kV RT on request
Stock choose
-
011411 NA2XSY 01X185/16 12/20 kV RT on request
Stock choose
-
011412 NA2XSY 01X185/25 12/20 kV RT on request
Stock choose
-
011413 NA2XSY 01X240/16 12/20 kV RT on request
Stock choose
-
011414 NA2XSY 01X240/25 12/20 kV RT on request
Stock choose
-
011415 NA2XSY 01X300/25 12/20 kV RT on request
Stock choose
-
012922 NA2XSY 1X300/50 12/20 kV RT on request
Stock choose
-
011416 NA2XSY 01X400/35 12/20 kV RT on request
Stock choose
-
012923 NA2XSY 1X400/50 12/20 kV RT on request
Stock choose
-
011417 NA2XSY 01X500/35 12/20 kV RT on request
Stock choose
-
014006 NA2XSY 01X630/35 12/20 kV RT on request
Stock choose
-
013532 NA2XSY 01X800/35 12/20 kV RT on request
Stock choose
-
011418 NA2XSY 01X50/16 18/30 kV RT on request
Stock choose
-
011419 NA2XSY 01X70/16 18/30 kV RT on request
Stock choose
-
012965 NA2XSY 01X70/25 18/30 kV RT on request
Stock choose
-
011420 NA2XSY 01X95/16 18/30 kV RT on request
Stock choose
-
011421 NA2XSY 01X120/16 18/30 kV RT on request
Stock choose
-
011422 NA2XSY 01X150/16 18/30 kV RT on request
Stock choose
-
011423 NA2XSY 01X150/25 18/30 kV RT on request
Stock choose
-
011424 NA2XSY 01X185/16 18/30 kV RT on request
Stock choose
-
011425 NA2XSY 01X185/25 18/30 kV RT on request
Stock choose
-
011426 NA2XSY 01X240/16 18/30 kV RT on request
Stock choose
-
011427 NA2XSY 01X240/25 18/30 kV RT on request
Stock choose
-
011428 NA2XSY 01X300/25 18/30 kV RT on request
Stock choose
-
011429 NA2XSY 01X400/35 18/30 kV RT on request
Stock choose
-
011430 NA2XSY 01X500/35 18/30 kV RT on request
Stock choose
-
013137 NA2XSY 01X630/35 18/30 kV RT on request
Stock choose
-
014099 NA2XSY 01X1000/35 18/30 kV RT on request
Stock choose
-

All images shown here are for illustrations and product reference purposes only.

The offered products of this online shop are aimed at entrepreneurs according to §14 BGB, traders, freelancer and public organisations. There is no sale for consumers.

Who we are.

Faber has numbered amongst the top providers in the cable and wire industry for over 68 years. We convince our customers with high-performing products and tested quality.

We are appreciated for our know-how, our service-orientation and our absolute adherence to delivery dates. Because we find: Nothing is more important than being a strong and dependable partner.

Contact.

Klaus Faber AG
Lebacher Straße 152 – 156
66113 Saarbrücken
Germany

Phone +49 681 97 11-289
Fax +49 681 97 11-289