flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C screened cable cable to a large extent oil resistant installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
038412Faber® EMV 2XSL(St)CYv-JB 4X1.5 0.6/1 kV BK
in stock
Presentation

Log in to see prices

New here? Register now
Price
034456Faber® EMV 2XSL(St)CYv-JB 4X2.5 0.6/1 kV BK
in stock
PresentationPrice
038413Faber® EMV 2XSL(St)CYv-JB 4X4 0.6/1 kV BK
in stock
PresentationPrice
034458Faber® EMV 2XSL(St)CYv-JB 4X6 0.6/1 kV BK
MOQ

MOQ: 7 km

Delivery time: approx. 19 weeks

PresentationPrice
038414Faber® EMV 2XSL(St)CYv-JB 4X10 0.6/1 kV BK
in stock
PresentationPrice
038415Faber® EMV 2XSL(St)CYv-JB 4X16 0.6/1 kV BK
in stock
PresentationPrice
038416Faber® EMV 2XSL(St)CYv-JB 4X25 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
038417Faber® EMV 2XSL(St)CYv-JB 4X35 0.6/1 kV BK
in stock
PresentationPrice
038418Faber® EMV 2XSL(St)CYv-JB 4X50 0.6/1 kV BK
in stock
PresentationPrice
038419Faber® EMV 2XSL(St)CYv-JB 4X70 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
038420Faber® EMV 2XSL(St)CYv-JB 4X95 0.6/1 kV BK
in stock
PresentationPrice
038421Faber® EMV 2XSL(St)CYv-JB 4X120 0.6/1 kV BK
in stock
PresentationPrice
038422Faber® EMV 2XSL(St)CYv-JB 4X150 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
038423Faber® EMV 2XSL(St)CYv-JB 4X185 0.6/1 kV BK
in stock
PresentationPrice
038424Faber® EMV 2XSL(St)CYv-JB 4X240 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
038425Faber® EMV 2XSL(St)CYv-JB 4X300 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
038398Faber® EMV 2XSL(St)CYv-JB 3X1.5 + 3G0.25 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
038399Faber® EMV 2XSL(St)CYv-JB 3X2.5 + 3G0.5 0.6/1 kV BK
in stock
PresentationPrice
038400Faber® EMV 2XSL(St)CYv-JB 3X4 + 3G0.75 0.6/1 kV BK
in stock
PresentationPrice
038401Faber® EMV 2XSL(St)CYv-JB 3X6 + 3G1 0.6/1 kV BK
in stock
PresentationPrice
038402Faber® EMV 2XSL(St)CYv-JB 3X10 + 3G1.5 0.6/1 kV BK
in stock
PresentationPrice
038403Faber® EMV 2XSL(St)CYv-JB 3X16 + 3G2.5 0.6/1 kV BK
in stock
PresentationPrice
038404Faber® EMV 2XSL(St)CYv-JB 3X25 + 3G4 0.6/1 kV BK
in stock
PresentationPrice
038405Faber® EMV 2XSL(St)CYv-JB 3X35 + 3G6 0.6/1 kV BK
in stock
PresentationPrice
038406Faber® EMV 2XSL(St)CYv-JB 3X50 + 3G10 0.6/1 kV BK
in stock
PresentationPrice
038407Faber® EMV 2XSL(St)CYv-JB 3X70 + 3G10 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
034465Faber® EMV 2XSL(St)CYv-JB 3X95 + 3G16 0.6/1 kV BK
in stock
PresentationPrice
034466Faber® EMV 2XSL(St)CYv-JB 3X120 + 3G16 0.6/1 kV BK
in stock
PresentationPrice
038408Faber® EMV 2XSL(St)CYv-JB 3X150 + 3G25 0.6/1 kV BK
in stock
PresentationPrice
038409Faber® EMV 2XSL(St)CYv-JB 3X185 + 3G35 0.6/1 kV BK
in stock
PresentationPrice
038410Faber® EMV 2XSL(St)CYv-JB 3X240 + 3G50 0.6/1 kV BK
in stock
PresentationPrice
038411Faber® EMV 2XSL(St)CYv-JB 3X300 + 3G70 0.6/1 kV BK
MOQ

MOQ: m

Delivery time: approx. 19 weeks

PresentationPrice
Customs Tariff Number (code number) 85444995900000000
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation XLPE
Core wrapping plastic foil
Screen aluminium foil + tinned copper braid
Screen coverage 75 %
Sheathing material PVC, enforced
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -30 - +70 °C
Permitted outer cable temperature, moved, °C -5 - +70 °C
Bending radius, fixed installation 10 x Ø
Bending radius, moving application 20 x Ø
Transfer impedance 250 Ohm/km
Core identification colours acc. to VDE 0293 (HD308)
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

The cable has been developed for connecting motors to inverse rectifiers under consideration of EMC-requirements. It may be used under medium mechanical stress for fixed installations and temporary movement. Also for outdoor installation, but not for direct burial. The cable is resistant to most usual oil and grease.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator