flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C cable to a large extent oil resistant festoon cable installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
053614BIT (N)3GRD5G-O 1X25 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

Presentation

Log in to see prices

New here? Register now
Price
053510BIT (N)3GRD5G-O 1X50 0.6/1 kV BK
in stock
PresentationPrice
053140BIT (N)3GRD5G-O 1X70 0.6/1 kV BK
in stock
PresentationPrice
053549BIT (N)3GRD5G-O 1X95 0.6/1 kV BK
in stock
PresentationPrice
053141BIT (N)3GRD5G-O 1X120 0.6/1 kV BK
in stock
PresentationPrice
053262BIT (N)3GRD5G-O 1X150 0.6/1 kV BK
in stock
PresentationPrice
053945BIT (N)3GRD5G-O 1X185 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053539BIT (N)3GRD5G-J 4G2.5 0.6/1 kV BK
in stock
PresentationPrice
053511BIT (N)3GRD5G-J 4G4 0.6/1 kV BK
in stock
PresentationPrice
053512BIT (N)3GRD5G-J 4G6 0.6/1 kV BK
in stock
PresentationPrice
053513BIT (N)3GRD5G-J 4G10 0.6/1 kV BK
in stock
PresentationPrice
053540BIT (N)3GRD5G-J 4G16 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053615BIT (N)3GRD5G-J 4G25 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053541BIT (N)3GRD5G-J 4G35 0.6/1 kV BK
in stock
PresentationPrice
053680BIT (N)3GRD5G-J 5G4 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053142BIT (N)3GRD5G-J 5G6 0.6/1 kV BK
in stock
PresentationPrice
053143BIT (N)3GRD5G-J 5G10 0.6/1 kV BK
in stock
PresentationPrice
053263BIT (N)3GRD5G-J 5G16 0.6/1 kV BK
in stock
PresentationPrice
053146BIT (N)3GRD5G-J 5G25 0.6/1 kV BK
in stock
PresentationPrice
054410BIT (N)3GRD5G-J 5G35 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053542BIT (N)3GRD5G-J 7G2.5 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053543BIT (N)3GRD5G-J 12G1.5 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053544BIT (N)3GRD5G-J 18G1.5 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053545BIT (N)3GRD5G-J 18G2.5 0.6/1 kV BK
in stock
PresentationPrice
053484BIT (N)3GRD5G-J 12G2.5 0.6/1 kV BK
in stock
PresentationPrice
053147BIT (N)3GRD5G-J 24G2.5 0.6/1 kV BK
in stock
PresentationPrice
053145BIT (N)3GRD5G-J 30G2.5 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
054573BIT (N)3GRD5G-J 36G2.5 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. week

PresentationPrice
053148BIT (N)3GRD5G-O 6X(2X1)C 0.6/1 kV BK
in stock
PresentationPrice
054435BIT (N)3GRD5G-O 9X(2X1)C 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053791BIT (N)3GRD5G-O 12X(2X1)C 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
054261BIT (N)3GRD5G-O 3X(2X1.5)C 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
054509BIT (N)3GRD5G-O 6X(2X1.5)C 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. week

PresentationPrice
053550BIT (N)3GRD5G-J 3X25+3G16/3 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053551BIT (N)3GRD5G-J 3X35+3G25/3 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053552BIT (N)3GRD5G-J 3X50+3G25/3 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
053553BIT (N)3GRD5G-J 3X70+3G35/3 0.6/1 kV BK
MOQ

MOQ: 3 km

Delivery time: approx. 23 weeks

PresentationPrice
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0250-812 (with reference to)
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation HEPR
Material inner sheath rubber GM1b
Sheathing material rubber 5GM5
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Max. temperature at conductor, °C 90 °C
Max. short circuit temperature at conductor, °C 250 °C
Permitted outer cable temperature, moved, °C -35 - +80 °C
Bending radius, fixed installation 4 x Ø
Bending radius, moving application 5 x Ø
Maximum tensile strength at the conductor 15 N/mm²
Operating speed festoon, m/min. 240 m/min.
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Power and control cable for high mechanical requirements, frequently bendings in only one direction, especially for use in trolley systems, drag chains on moving parts of machines, conveyor facilities. Suitable for dry, humid and wet rooms and for outdoor use.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator