cable with circuit integrity 30 min cable conform to Low Voltage directive cable with function maintainance 180 min flame retardant acc. IEC 60332-3-24 cable with low smoke IEC 61034 cable halogen-free max. permitted temperature at conductor 90 °C cable with VDE-certification
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
011505(N)HXCH E30 2X1.5/1.5 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

Presentation

Log in to see prices

New here? Register now
Price
011506(N)HXCH E30 2X2.5/2.5 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
011507(N)HXCH E30 2X4/4 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
013253(N)HXCH E30 2X6/6 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
015652(N)HXCH E30 2X10/10 RE OR
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
011278(N)HXCH E30 3X1.5/1.5 RE OG
MOQ

MOQ: 10 km

Delivery time: approx. 15 weeks

PresentationPrice
011215(N)HXCH E30 3X2.5/2.5 RE OG
in stock
PresentationPrice
013753(N)HXCH E30 3X4/4 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
013754(N)HXCH E30 3X6/6 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
013755(N)HXCH E30 3X10/10 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
013756(N)HXCH E30 3X16/16 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
013856(N)HXCH E30 3X25/16 OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
013857(N)HXCH E30 3X50/25 RM OG
MOQ

MOQ: 5 km

Delivery time: approx. 15 weeks

PresentationPrice
013858(N)HXCH E30 3X70/35 RM OG
MOQ

MOQ: 5 km

Delivery time: approx. 15 weeks

PresentationPrice
013859(N)HXCH E30 3X95/50 RM OG
MOQ

MOQ: 5 km

Delivery time: approx. 15 weeks

PresentationPrice
013860(N)HXCH E30 3X120/70 RM OG
MOQ

MOQ: 5 km

Delivery time: approx. 15 weeks

PresentationPrice
011831(N)HXCH E30 3X150/70 RM OG
MOQ

MOQ: 5 km

Delivery time: approx. 15 weeks

PresentationPrice
011832(N)HXCH E30 3X185/95 RM OG
MOQ

MOQ: 5 km

Delivery time: approx. 15 weeks

PresentationPrice
011280(N)HXCH E30 4X1.5/1.5 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
011281(N)HXCH E30 4X2.5/2.5 RE OG
in stock
PresentationPrice
011282(N)HXCH E30 4X4/4 RE OG
in stock
PresentationPrice
011226(N)HXCH E30 4X6/6 RE OG
MOQ

MOQ: 5 km

Delivery time: approx. 15 weeks

PresentationPrice
011224(N)HXCH E30 4X10/10 RE OG
in stock
PresentationPrice
011181(N)HXCH E30 4X16/16 OG
in stock
PresentationPrice
011167(N)HXCH E30 4X25/16 OG
in stock
PresentationPrice
011183(N)HXCH E30 4X35/16 OG
in stock
PresentationPrice
011227(N)HXCH E30 4X50/25 RM OG
in stock
PresentationPrice
011168(N)HXCH E30 4X70/35 RM OG
in stock
PresentationPrice
011184(N)HXCH E30 4X95/50 RM OG
in stock
PresentationPrice
011274(N)HXCH E30 4X120/70 RM OG
in stock
PresentationPrice
011275(N)HXCH E30 4X150/70 RM OG
in stock
PresentationPrice
011276(N)HXCH E30 4X185/95 RM OG
in stock
PresentationPrice
011277(N)HXCH E30 4X240/120 RM OG
in stock
PresentationPrice
011279(N)HXCH E30 7X1.5/2.5 RE OR
in stock
PresentationPrice
011283(N)HXCH E30 7X2.5/2.5 RE OG
MOQ

MOQ: 7 km

Delivery time: approx. 15 weeks

PresentationPrice
011284(N)HXCH E30 12X1.5/2.5 RE OG
in stock
PresentationPrice
011285(N)HXCH E30 12X2.5/4 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
014465(N)HXCH E30 14X2.5/6 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
013621(N)HXCH E30 19X1.5/2.5 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
013622(N)HXCH E30 24X1.5/2.5 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
013820(N)HXCH E30 19X1.5/4 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
013821(N)HXCH E30 24X1.5/6 RE OG
MOQ

MOQ: 6 km

Delivery time: approx. 15 weeks

PresentationPrice
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0266
Conductor material copper, bare
Conductor construction class 1, from 25 sqmm class 2
Insulation FRNC-compound HI1
Concentric conductor Cu
Sheathing material FRNC-compound HM1
Colour of outer sheath orange
Flame-retardant VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
Smoke density DIN EN 61034/IEC 61034
Halogen-free DIN EN 50267/IEC 60754
Fire-resistant VDE 0472-814/IEC 60331-1/IEC 60331-11 (FE 180)/EN 50200
Circuit integrity E30
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -5 - +70 °C
Bending radius, fixed installation 12 x Ø
Core identification colours acc. to HD 308; more than 5 cores: numbers
Conductor shape round
Colour of outer sheath orange
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min.= IEC 60331). Furthermore the cable passed the test of 30 min. circuit integrity according to DIN 4102 part 12 (E 30) for all so-called standard installation systems (ladder, tray and ceiling) and is suitable for installation in fire alarm systems, safety lightning and other emergency electrical supply systems according to VDE 0108. A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 800 °C is approximately four times higher than at 20 °C and the current carrying capacity is reduced respectively.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator