flame retardant acc. IEC 60332-1-2 screened cable cable to a large extent oil resistant festoon cable max. permitted temperature at conductor 90 °C installation in free air without UV-protection (cable UV-resistant) cable conform to Low Voltage directive
0519930400500
drum 500 m
Invalid input!
MOQ

MOQ: 6 km

Delivery time: approx. 23 weeks

Price
Price
Price
0519930401000
drum 1000 m
Invalid input!
MOQ

MOQ: 6 km

Delivery time: approx. 23 weeks

Price
Price
Price
0519930400000
cut length
Invalid input!
in stock
Price
Price
Price

Log in to see prices

New here? Register now
0
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0250-812 (with reference to)
Conductor material bare copper strand
Conductor construction Class 5 = flexible
Insulation HEPR
Material inner sheath rubber EM6
Screen copper braid, tinned + synthetic fibre
Screen coverage 80 %
Sheathing material rubber EM7
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant EN 60811-404
Ozone-resistant yes
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -50 - +80 °C
Permitted outer cable temperature, moved, °C -35 - +80 °C
Maximum tensile strength at the conductor 15 N/mm²
Operating speed festoon, m/min. 240 m/min.
Number of cores 12
Nominal cross section, sqmm 1.5 mm²
Conductor resistance 13.3 Ohm/km
outer diameter approx. 21.00 mm
Tensile strength (permanent) 270 N
Tensile strength (dynamic) 540 N
Copper weight (GER) 215
metal base Cu 150 EUR/100 kg
net weight per 1000 549 kg
Unit of measurement metre
crane cables / hoist cables yes
Nominal voltage 0,6/1 kV
Sheathing material rubber
Cable shape round
Halogen-free no
Oil-resistant yes
Colour black
Conductor construction class 5 = fine stranded
Insulation rubber

Screened Power and control cable for high mechanical requirements, frequently bendings in only one direction, especially for use in trolley systems on moving parts of machines and crans. Suitable for dry, humid and wet rooms and for outdoor use combined with specific EMC (electromagnetic compatibility) requirements.