flame retardant acc. IEC 60332-1-2 cable to a large extent oil resistant cable for reeling application min. installation temperature -40 °C installation in free air without UV-protection (cable UV-resistant)
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
0537243X25 + 2X16/2 + 12E9 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

Aufmachung

Log in to see prices

New here? Register now
Preis
0537253X25 + 2X16/2 + 12G50 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0537263X25 + 2X16/2 + 12G62.5 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0534983X35 + 2X16/2 + 12G50 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0539773X50 + 2X25/2 + 12E9 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0539783X50 + 2X25/2 + 12G50 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0539793X50 + 2X25/2 + 12G62.5 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0535973X70 + 2X25/2 + 24E9 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0537203X70 + 2X35/2 + 12E9 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0537213X70 + 2X35/2 + 12G50 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0524463X70 + 2X35/2 + 12G62.5 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0532973X95 + 2X50/2 + 12E9 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0529503X95 + 2X50/2 + 12G62.5 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0524473X120 + 2X70/2 + 12G62.5 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0542133X150 + 2X70/2 + 12E9 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0542143X150 + 2X70/2 + 12G50 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0524483X150 + 2X70/2 + 12G62.5 0.6/1 kV BK
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0546333X150 + 2X70/2 + 24E9 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. week

AufmachungPreis
0544403X185 + 2X95/2 + 12E9 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0544413X185 + 2X95/2 + 12G50 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0544423X185 + 2X95/2 + 12G62.5 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0534353X240 + 2X120/2 + 12E9/125 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0535173X240 + 2X120/2 + 24E9 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. 23 weeks

AufmachungPreis
0545613X120 + 70 + (6X2.5)C + 12E9 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. week

AufmachungPreis
0545623X120 + 70 + (6X2.5)C + 12G50 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. week

AufmachungPreis
0545633X120 + 70 + (6X2.5)C + 12G62.5 0.6/1 kV SW
MOQ

MOQ: 1 km

Delivery time: approx. week

AufmachungPreis
Customs Tariff Number (code number) 85444995900000000
Standard VDE 0250-814 (wih reference to)
Conductor material copper, bare
Conductor construction Class 5 = flexible
Insulation rubber (EPR) 3GI3
Arrangement of protective conductors split in the outer interstices
Material inner sheath Gummi 5GM3
Torsion protection polyester braid
Torsion +/- 50 °/m
Sheathing material rubber (CR) 5GM5
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
Oil-resistant EN 60811-2-1
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C -40 - +80 °C
Permitted outer cable temperature, moved, °C -40 - +80 °C
Bending radius, fixed installation 4 x Ø
Bending radius, moving application 5 x Ø
Maximum tensile strength at the conductor 20 N/mm²
Operating speed 180 m/min.
Core identification colours acc. to VDE 0293 (HD308)
metal base Cu 150 EUR/100 kg
Unit of measurement metre
crane cables / hoist cables yes

These cables are intended for applications where frequent winding and unwinding is necessary during operation, in particular with simultaneous tensile strain and/or torsional stress and/or forced guidance of the cable. Where excessive stress, particularly high dynamic tensile force may be expected, e.g. as a result of high acceleration figures, the permissible stress limits have to be determined individually. The cables can be manufactured to order or project-specific with E9/125, 50/125 or 62.5/125 fibres or their various combinations.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator