flame retardant acc. IEC 60332-1-2 max. permitted temperature at conductor 90 °C min. installation temperature -5 °C installation in free air only with UV-protection (cable not UV-resistant) cable for use in water cable suitable for direct burial cable with EAC-approval cable with VDE-certification
p/nr.Part nameAvailabilityPackagingEUR netto pre-metal per 1.000 m.
011392NA2XSY 1X50/16 6/10 kV RD
MOQ

MOQ: 6 km

Delivery time: approx. 30 weeks

Aufmachung

Log in to see prices

New here? Register now
Preis
011393NA2XSY 1X70/16 6/10 kV RD
MOQ

MOQ: 6 km

Delivery time: approx. 30 weeks

AufmachungPreis
012614NA2XSY 1X70/35 6/10 kV RD
MOQ

MOQ: 6 km

Delivery time: approx. 30 weeks

AufmachungPreis
011394NA2XSY 1X95/16 6/10 kV RD
MOQ

MOQ: 6 km

Delivery time: approx. 30 weeks

AufmachungPreis
011395NA2XSY 1X120/16 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
012615NA2XSY 1X120/50 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011396NA2XSY 1X150/16 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011397NA2XSY 1X150/25 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011398NA2XSY 1X185/16 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011399NA2XSY 1X185/25 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011400NA2XSY 1X240/16 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011401NA2XSY 1X240/25 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011402NA2XSY 1X300/25 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011403NA2XSY 1X400/35 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011404NA2XSY 1X500/35 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
014005NA2XSY 1X630/35 6/10 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011405NA2XSY 1X50/16 12/20 kV RD
MOQ

MOQ: 6 km

Delivery time: approx. 30 weeks

AufmachungPreis
011406NA2XSY 1X70/16 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011407NA2XSY 1X95/16 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011408NA2XSY 1X120/16 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
013031NA2XSY 1X120/25 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

AufmachungPreis
011409NA2XSY 1X150/16 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011410NA2XSY 1X150/25 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011411NA2XSY 1X185/16 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011412NA2XSY 1X185/25 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011413NA2XSY 1X240/16 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011414NA2XSY 1X240/25 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011415NA2XSY 1X300/25 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
012922NA2XSY 1X300/50 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

AufmachungPreis
011416NA2XSY 1X400/35 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
012923NA2XSY 1X400/50 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 10 weeks

AufmachungPreis
011417NA2XSY 1X500/35 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
014006NA2XSY 1X630/35 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
013532NA2XSY 1X800/35 12/20 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011418NA2XSY 1X50/16 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011419NA2XSY 1X70/16 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
012965NA2XSY 1X70/25 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011420NA2XSY 1X95/16 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011421NA2XSY 1X120/16 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011422NA2XSY 1X150/16 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011423NA2XSY 1X150/25 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011424NA2XSY 1X185/16 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011425NA2XSY 1X185/25 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011426NA2XSY 1X240/16 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011427NA2XSY 1X240/25 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011428NA2XSY 1X300/25 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011429NA2XSY 1X400/35 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
011430NA2XSY 1X500/35 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
013137NA2XSY 1X630/35 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
014099NA2XSY 1X1000/35 18/30 kV RD
MOQ

MOQ: 5 km

Delivery time: approx. 30 weeks

AufmachungPreis
Customs Tariff Number (code number) 85446090000000000
Standard VDE 0276-620
Conductor material aluminium
Conductor construction Class 2 = stranded
Insulation XLPE DIX8
Electrical field control inner and outer semiconducting layer (triple extrusion)
Screen Copper wires + counter helix
Sheathing material PVC DMV6
Colour of outer sheath red
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
For outdoor use yes
Max. temperature at conductor, °C 90 °C
Permitted outer cable temperature, fixed, °C 70 °C
Permitted outer cable temperature, moved, °C -5 - +70 °C
Bending radius, fixed installation 15 x Ø
Conductor shape (Faber) RMv
Number of cores 1
Colour of outer sheath red
metal base Al (ger) 0 EUR/100 kg
metal base Cu 0 EUR/100 kg
Unit of measurement metre

For installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks. The good installation properties of this cable make installation easy, even on difficult routes. According to VDE 0276-603 cables must be protected from sunlight.

All images shown here are for illustrations and product reference purposes only.

Freight cost extra. Prices plus metal regarding the daily market price.

Contact
Cable calculator